首页 | 本学科首页   官方微博 | 高级检索  
检索        


Comparison of integrated whole-body [11C]choline PET/MR with PET/CT in patients with prostate cancer
Authors:Michael Souvatzoglou  Matthias Eiber  Toshiki Takei  Sebastian Fürst  Tobias Maurer  Florian Gaertner  Hans Geinitz  Alexander Drzezga  Sibylle Ziegler  Stephan G Nekolla  Ernst J Rummeny  Markus Schwaiger  Ambros J Beer
Institution:1. Department of Nuclear Medicine, Technische Universit?t München, Ismaningerstr. 22, 81675, Munich, Germany
2. Department of Radiology, Technische Universit?t München, Ismaningerstr. 22, 81675, Munich, Germany
3. Department of Urology, Technische Universit?t München, Ismaningerstr. 22, 81675, Munich, Germany
4. Department of Radiation Oncology, Technische Universit?t München, Ismaningerstr. 22, 81675, Munich, Germany
Abstract:

Purpose

To evaluate the performance of conventional 11C]choline PET/CT in comparison to that of simultaneous whole-body PET/MR.

Methods

The study population comprised 32 patients with prostate cancer who underwent a single-injection dual-imaging protocol with PET/CT and subsequent PET/MR. PET/CT scans were performed applying standard clinical protocols (5 min after injection of 793?±?69 MBq 11C]choline, 3 min per bed position, intravenous contrast agent). Subsequently (52?±?15 min after injection) PET/MR was performed (4 min per bed position). PET images were reconstructed iteratively (OSEM 3D), scatter and attenuation correction of emission data and regional allocation of 11C]choline foci were performed using CT data for PET/CT and segmented Dixon MR, T1 and T2 sequences for PET/MR. Image quality of the respective PET scans and PET alignment with the respective morphological imaging modality were compared using a four point scale (0–3). Furthermore, number, location and conspicuity of the detected lesions were evaluated. SUVs for suspicious lesions, lung, liver, spleen, vertebral bone and muscle were compared.

Results

Overall 80 lesions were scored visually in 29 of the 32 patients. There was no significant difference between the two PET scans concerning number or conspicuity of the detected lesions (p not significant). PET/MR with T1 and T2 sequences performed better than PET/CT in anatomical allocation of lesions (2.87?±?0.3 vs. 2.72?±?0.5; p?=?0.005). The quality of PET/CT images (2.97?±?0.2) was better than that of the respective PET scan of the PET/MR (2.69?±?0.5; p?=?0.007). Overall the maximum and mean lesional SUVs exhibited high correlations between PET/CT and PET/MR (ρ?=?0.87 and ρ?=?0.86, respectively; both p?<?0.001).

Conclusion

Despite a substantially later imaging time-point, the performance of simultaneous PET/MR was comparable to that of PET/CT in detecting lesions with increased 11C]choline uptake in patients with prostate cancer. Anatomical allocation of lesions was better with simultaneous PET/MR than with PET/CT, especially in the bone and pelvis. These promising findings suggest that 11C]choline PET/MR might have a diagnostic benefit compared to PET/CT in patients with prostate cancer, and now needs to be further evaluated in prospective trials.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号