Gap formation after single lateral row versus dual-row suture bridge cuff repair: An ovine biomechanical model
Institution:1. Department of Orthopaedic Surgery, Singapore General Hospital, 20 College Road, 169608, Singapore;2. School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Ave, 639798, Singapore;1. Department of Orthopaedic Surgery, Ichinomiya Nishi Hospital, Japan;2. Department of Orthopaedic Surgery, Aichi Medical University, Japan;1. Shandong University Cheeloo College of Medicine, Wenhua West Road 44#, Jinan, Shandong Province, 250012, PR China;2. Department of Orthopedics, Qilu Hospital of Shandong University, Wenhua West Road 107#, Jinan, Shandong Province, 250012, PR China;3. Department of Spine Surgery of Traditional Chinese Hospital Affiliated with Xinjiang Medical University, Urumqi, Xinjiang, PR China;1. Department of Orthopaedic Surgery, Center for Joint Disease, Chonnam National University Hwasun Hospital, Jeonnam, South Korea;2. Department of Orthopaedic and Traumatology, Faculty of Medicine, Sebelas Maret University, Prof. Dr. R. Soeharso Orthopaedic Hospital, Solo, Indonesia;1. Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University, Seoul, Korea;2. Department of Orthopaedic Surgery, National Medical Center, Seoul, Korea;3. Department of Orthopaedic Surgery, Wonkwang University Sanbon Hospital, Gyeonggi-do, Korea;4. Department of Orthopaedic Surgery, Seoul Medical Center, Seoul, Korea;5. Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University, Gyeongsangnam-do, Korea
Abstract:BackgroundThe aim of this study is to compare two types of suture bridging constructs; a laterally based bridging single row (SR) construct and a classic dual row (DR) suture bridge construct. The hypothesis is that the DR construct will demonstrate superior biomechanical properties.MethodsSix matched pairs of sheep infraspinatus tendon tears repaired with these two different types of suture bridging techniques were tested for gap formation, ultimate failure load and mode of failure. The specimens were pre-cycled for 10 cycles before they were subjected to a constant pre-load of 10N. The specimens were then subjected to cyclic loading at a speed of 8.33 mm/s. The test was stopped after every 500 cycles for a total of 3000 cycles.ResultsMean gap formation after 3000 cycles was lower in the DR group (0.81 ± 0.2 mm versus 2.44 ± 0.27 mm; p = 0.002). Mean change in gap (with every 500 cycles) was also lesser for the DR group after 1500 cycles. DR repairs failed at a higher load (523.4 ± 80.4 N) compared to the SR repairs (452.3 ± 66.3 N) but this did not reach significance. All repairs failed with sutures pulling through the tendon during load to failure testing.ConclusionsGap formation is significantly lower with a dual row suture bridge construct than a laterally based bridging single row construct.Level of evidenceBiomechanical study.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号