摘    要:目前各级医院使用的医疗设备出现故障时,无论是自己维修还是厂家维修通常选择更换相应备件的维修方式,而进口医疗器械价格昂贵,相应的维修费用较高。针对美国美林心电运动平板出现的故障,可通过替换设备核心电路板的变压器和继电器而将其成功修复。

关 键 词:无线遥测  运动平板  继电器

Troubleshooting for US Merrill Lynch treadmill
LIU Xin-jian,JIA Hong-yuan.Troubleshooting for US Merrill Lynch treadmill[J].China Medical Equipment,2012(8):91-92.
Authors:LIU Xin-jian  JIA Hong-yuan
Institution:Deoartment of Medical Engineering, the First People's Hospital of Aksu City, Aksu 845000, China.
Abstract:In general, part replacement was usually employed upon occurrence of failure in all levels of medical institutions. However, the imported parts were high in price. So, we successfully performed troubleshooting for US Merrill Lynch treadmill by replacing the core transformer and relay.