首页 | 本学科首页   官方微博 | 高级检索  
检索        

不同对比剂及注射速度对64排螺旋CT冠状动脉成像的影响
引用本文:王晓敏,陈红,刘斌,周勇,沈云.不同对比剂及注射速度对64排螺旋CT冠状动脉成像的影响[J].安徽医学,2013,34(3):315-318.
作者姓名:王晓敏  陈红  刘斌  周勇  沈云
作者单位:安徽医科大学第一附属医院放射科,合肥,230022;安徽医科大学第二附属医院核医学科,合肥,230601;北京GE中国CT影像研究室,100176
摘    要:目的比较在64排螺旋CT冠状动脉造影时,不同浓度对比剂以不同速度注射时对血管增强效果及图像质量的影响。方法将接受64排螺旋CT冠状动脉检查的患者,选取体质量指数(BMI)为20.20~25.80 kg/m2的患者60例,分为A、B、C组,每组20例。A组:使用350 mgI/ml浓度的欧乃派克,注射流率为4.5 ml/s(碘流量1 575 mgI/s);B组:应用浓度为370 mgI/ml的优维显,团注流率为4.3 ml/s(碘流量1 591 mgI/s);C组:使用350 mgI/ml浓度的欧乃派克,注射速度为4.3 ml/s(碘流量1 505 mgI/s)。分别对A组与C组、A组与B组、B组与C组的升主动脉、降主动脉、左主干及左前降支、左回旋支、右主干近段的强化程度及图像质量进行比较。结果 3组患者左回旋支的增强平均值均较本组其它血管的强化数值偏小。除左回旋支外,A组其余血管增强平均值均大于C组。B组各段血管的强化平均值均大于相应的A组及C组;除B组与C组患者升主动脉及降主动脉的增强程度存在显著性差异外,A组与C组、A组与B组、B组与C组的其它各段血管的增强程度没有显著性差异。C组4支血管图像质量评分平均值大于A组和B组;A组与B组图像质量评分没有显著性差异,A组和C组、B组与C组4支血管间质量评分均存在显著性差异;350 mgI/ml浓度对比剂可获得更佳增强效果图像。结论64排螺旋CT冠状动脉成像对比剂浓度及注射速度的优化具有可行性,并能获得更佳的增强图像。

关 键 词:冠状动脉  体层摄影术  X线计算机  对比剂

Influence of different contrast media on injecting different coronary artery with 64-detector row helical CT
Institution:Wang Xiaomin,Chen Hong,Liu Bin,et al Department of Radiology,the First Affiliated Hospital of Anhui Medical University,Hefei 230022,China
Abstract:Objective To investigate the effect of different contrast media with different injection speeds on the enhanced effect of coronary angiography by 64-detector row helical CT.Methods Sixty consecutive patients with the BMI of 20.20 ~25.80 kg/m2 undergoing coronary angiography by 64-slice CT were divided into three groups.Group A was injected contrast medium of 350 mgI/ml with the speed of 4.5 ml/s and group C was 4.3 ml/s,group B was injected contrast medium of 370 mgI/ml with the speed of 4.3 ml/s.The enhanced effect and picture quality of three groups in ascending aorta,descending aorta,the trunk and branch of coronary artery were compared.Results The enhanced values of LCX were smaller than those of the other vessels in the same group.Except LCX,the enhanced values in other vessels of group A exceeded those of group C.The enhanced values of group B exceeded those of group A and C;except in aorta of group B and C,the difference of enhancement in other vessels between group A and C,group A and B,group B and C was not significant.Except left circumflex,the enhanced values of group C were less than those of group A.The average score of picture quality in group C surpassed that in group A and B.The score between group A and B existed significant difference,but there was no significant difference between group A and C,group B and C.The contrast medium of 350 mgI/ml could obtain the optimal enhanced image.Conclusion The optimum concentration of contrast medium in coronary angiography by 64-detector row helical CT is feasible and more excellent enhanced image can be gained.
Keywords:Coronary artery  Tomography  X-ray computed  Contrast medium
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《安徽医学》浏览原始摘要信息
点击此处可从《安徽医学》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号