首页 | 本学科首页   官方微博 | 高级检索  
     


Responsiveness and minimal clinically important difference of the Chinese version of the Low Vision Quality of Life Questionnaire after cataract surgery
Authors:Wen-Wen Xue  Pei Zhang  Hai-Dong Zou
Affiliation:Department of Ophthalmology, Shanghai Eye Diseases Prevention and Treatment Center, Shanghai 200040, China; Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200080, China,Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200080, China; Department of Ophthalmology, Shanghai Gonghui Hospital, Shanghai 200041, China and Department of Ophthalmology, Shanghai Eye Diseases Prevention and Treatment Center, Shanghai 200040, China; Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200080, China
Abstract:AIM: To investigate the Chinese version of the Low Vision Quality of Life Questionnaire (CLVQOL) as an instrument for obtaining clinically important changes after cataract surgery.METHODS: Patients underwent cataract surgery in Shanghai General Hospital, Shanghai Jiao Tong University, who fit the inclusion criteria were recruited. Two CLVQOLs were administered, including a preoperative CLVQOL and a CLVQOL at the end of the 3mo follow-up period, and were completed using face-to-face interviews or phone interviews conducted by trained investigators. The minimal clinically important difference (MCID) was calculated using an anchor-based method and a distribution method. In addition, the responsiveness of the questionnaire was measured.RESULTS: A total of 155 residents were enrolled. The average visual acuity (VA) preoperatively was 0.08 (SD=0.05), and it increased to 0.47 (SD=0.28) at the end of follow-up. Statistically significant positive changes in the CLVQOL scores indicated significant improvement of vision related quality of life after cataract surgery. With the larger value between the two results as the final value, the MCID values of the CLVQOL (scores of the four scales as well as the total score) were 8.94, 2.61, 4.34, 3.10 and 17.63, respectively. The CLVQOL has both good internal and external responsiveness.CONCLUSION: CLVQOL scores are appropriate instruments for obtaining clinically important changes after cataract surgery. This study is an effective exploration for establishing cataract surgery efficacy standards, which helps clinical and scientific research workers in ophthalmology to gain a more in-depth understanding when using CLVQOL.
Keywords:responsiveness   minimal clinically important difference   Chinese Version of the Low Vision Quality of Life Questionnaire   Chinese
点击此处可从《国际眼科》浏览原始摘要信息
点击此处可从《国际眼科》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号