MSCT实时造影剂跟踪技术在冠状动脉成像中的临床优选研究 |
| |
作者单位: | 第四军医大学西京医院 |
| |
摘 要: | 目的:研究16层螺旋CT冠状动脉成像中的实时造影剂跟踪触发技术(Surestart)的最佳阈值。方法:60例患者行冠状动脉增强扫描。分别对照不同触发扫描CT阈值和心率下的冠状动脉成像效果,a组心率<70次/min,b组心率>70次/min。按从优到劣A、B、C3个质量等级,逐一对照2种检查方法图像质量并进行统计学分析。结果:160HU触发扫描组b组图像质量优,180HU组a组图像质量优。结论:Surestart最佳阈值为:以4.0ml/s为注射流率,心率<70次/min的CT阈值为180HU;心率大于>70次/min的CT阈值为160HU。
|
关 键 词: | 冠状动脉 血管造影术 体层摄影 X线计算机 |
Optimization Study of MSCT Surestart Tracking and Triggering Technique for Imaging of Coronary Artery |
| |
Authors: | LIU Kai ZHAO Hong-liang WEI Meng-qi |
| |
Abstract: | Objective To investigate the optimum threshold value of tracking and triggering technique (surestart) in imaging of coronary artery by 16-slice row CT. Methods 60 patients enrolled in the enhanced scan of coronary artery imaging were divided into 2 groups (group a : heart rate < 70 beats/per minute; group b: heart rate >70 beats/per minute ). The quality of images collected under different threshold value and heart rate was compared. The image quality of coronary artery was ranked by 3 levels, namely, level A, B and C. The data were statistically analyzed. Results The image quality triggered by 160 HU of group b was level A. The image quality triggered by 180 HU of group a was level A. Conclusion The optimum surestart is 180 HU when the heart rate <70 beats/per minute and the injection rate is 4.0ml/s. The optimum CT trigger threshold would be 160 HU when the heart rate is>70 beats/per minute. |
| |
Keywords: | coronary artery angiography tomography X-ray computed |
本文献已被 CNKI 等数据库收录! |