首页 | 本学科首页   官方微博 | 高级检索  
     


MEASUREMENT OF THE AXIAL WAVEFRONT ABERRATION OF THE HUMAN EYE
Authors:G. Walsh   W. N. Charman
Affiliation:Department of Ophthalmic Optics, University of Manchester Institute of Science and Technology, PO Box 88, Sackville Street, Manchester M60 1QD, U.K.
Abstract:An objective variation of Howland and Howland's subjective crossed-cylinder aberroscope method of estimating ocular aberration is described. An ophthalmoscopic arrangement allows the distorted retinal image of the aberroscope grid to be directly photographed for later analysis. Results for 10 subjects show that the ocular wavefront aberration near the visual axis is rarely symmetrical about the pupil centre and that, as a result, the phase transfer function is generally non-zero. Calculated modulation transfer functions at various pupil diameters broadly agree with those of earlier authors but suggest that marked differences occur between individual eyes when the pupil diameter exceeds about 3 mm.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏