首页 | 本学科首页   官方微博 | 高级检索  
     


A multicenter evaluation of near-infrared autofluorescence imaging of parathyroid glands in thyroid and parathyroid surgery
Affiliation:1. Department of Endocrine Surgery, Endocrinology and Metabolism Institute, Cleveland Clinic, Cleveland, OH;2. Massachusetts Eye and Ear, Massachusetts General Hospital, Harvard Medical School, Boston, MA;3. Division of Surgery, Department of Head and Neck Surgery, The University of Texas MD Anderson Cancer Center, Houston, TX;4. Head and Neck Endocrine Surgery, Sarasota Memorial Health Care System, Sarasota, FL;5. Division of General Surgery, Department of Surgery, Stanford University School of Medicine, CA;6. Division of Endocrine Surgery, Department of Surgery, University of Arizona College of Medicine, Banner - University Medical Center, Phoenix, AZ;7. Department of Surgery, University of California San Francisco, CA
Abstract:BackgroundThe usefulness of incorporating near-infrared autofluorescence into the surgical workflow of endocrine surgeons is unclear. Our aim was to develop a prospective registry and gather expert opinion on appropriate use of this technology.MethodsThis was a prospective multicenter collaborative study of patients undergoing thyroidectomy and parathyroidectomy at 7 academic centers. A questionnaire was disseminated among 24 participating surgeons.ResultsOverall, 827 thyroidectomy and parathyroidectomy procedures were entered into registry: 42% of surgeons found near-infrared autofluorescence useful in identifying parathyroid glands before they became apparent; 67% correlated near-infrared autofluorescence pattern to normal and abnormal glands; 38% of surgeons used near-infrared autofluorescence, rather than frozen section, to confirm parathyroid tissue; and 87% and 78% of surgeons reported near-infrared autofluorescence did not improve the success rate after parathyroidectomy or the ability to find ectopic glands, respectively. During thyroidectomy, 66% of surgeons routinely used near-infrared autofluorescence to rule out inadvertent parathyroidectomy. However, only 36% and 45% felt near-infrared autofluorescence decreased inadvertent parathyroidectomy rates and improved ability to preserve parathyroid glands during central neck dissections, respectively.ConclusionThis survey study identified areas of greatest potential use for near-infrared autofluorescence, which can form the basis of future objective trials to document the usefulness of this technology.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号