Urine test strips: reliability of semi-quantitative findings under tropical conditions
Authors:Christoph Kaiser  Felix Bergel  Ekkehard Doehring-Schwerdtfeger  Hermann Feldmeier  Jochen H. H. Ehrich
Affiliation:(1) Division of Tropical Paediatrics, University of Heidelberg, Federal Republic of Germany;(2) Kinderklinik der Medizinischen Hochschule Hannover, Konstanty-Gutschow-Strasse 8, 3000 Hannover 61, Federal Republic of Germany;(3) Institute of Medical Parasitology, University of Bonn, Federal Republic of Germany;(4) Landesinstitut für Tropenmedizin, Berlin, Federal Republic of Germany
Abstract:Semi-quantitative urinalysis with urine reagent strips (URS) for erythrocyturia (EU), leucocyturia (LU) and proteinuria (PU) was performed in Congolese and Sudanese school children withSchistosoma haematobium and/orS.mansoni infection. Quantitative urinalysis was performed on the same specimen using microscopy and a Neubauer counting chamber for EU and LU and the Coomassie blue dye-binding assay for PU. Microscopically detectable EU of more than 10 cells/mgrl was found in 63% of all samples and LU of more than 20 cells/mgrl was found in 60% of all samples. With the Coomassie blue method, PU of more than 150 mg/l was detected in 51% of all samples. URS gave positive results of grade 1–3 for EU in 69% of all samples, for LU in 63% of all samples and for PU in 66% of all samples. The sensitivity and specificity of URS compared with standard reference methods were as follows: EU 95% and 75%, LU 81% and 81% and PU 90% and 56%. When the results of all three test were combined, URS differentiated abnormal from normal urine specimens with a sensitivity of 94% and a specificity of 70%. Median quantitative results showed a good correlation with semiquantitative URS readings for all parameters, but there was a wide range of URS scores.We concluded that URS sensitively detect urinary abnormalities and thus may be used as a general screening method under field conditions when more specific methods cannot be performed. In the hospital laboratory,urine microscopy with a counting chamber would be preferred to URS as a sole method for EU and LU detection; URS is useful for the detection of PU in the tropical hospital laboratory where an appropriate quantitative method with a better specificity may not be available.
Keywords:Urine reagent strips  Erythrocyturia  Leucocyturia  Proteinuria  Schistosomiasis
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号