首页 | 本学科首页   官方微博 | 高级检索  
     


Fluorometric microassay of trypsin and enteropeptidase in children — comparison with a titrimetic assay
Authors:JOHN D. MITCHELL  ISABELLA M. MESSINA
Affiliation:Prince of Wales Children's Hospital, Randwick and University of New South Wales, Sydney, NSW
Abstract:Abstract Two trypsin assay methods for the estimation of this enzyme in duodenal fluid from children have been compared. Assay results for a fluorometric method based on the use of N-carbobenzoxy-diglycyl-L-arginyl-2-naphthylamide hydrochloride (GANA) as the trypsin substrate were found to correlate well (r=0.91, P<0.001) with those obtained with a much less sensitive titrimetric assay which used benzoylarginine ethylester hydrochloride (BAEE) as substrate. The higher sensitivity of the fluorometric assay has allowed accurate determination of trypsin activity in 10 μl aliquots of duodenal fluid. This low volume requirement makes the assay suitable for studies on infants of all ages and conserves duodenal fluid for use in other investigations often warranted during the assessment of childhood malabsorption.
The fluorometric assay has also been used to monitor the separation of enteropeptidase from trypsin(ogen) by chromatography on Sephacryl S-200 in samples of duodenal fluid from two children. Different proteolytic pathway deficiencies were confirmed in these children.
Keywords:enteropeptidase/trypsin assay    malabsorption    pancreas    proteolytic enzyme deficiency
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号