注射用磷酸肌酸钠中的微量钡含量测定研究 |
| |
引用本文: | 陈斌,潘俊芳,林峰,叶隽,余岳林,张少敏.注射用磷酸肌酸钠中的微量钡含量测定研究[J].中国药品标准,2011,12(4):252-254. |
| |
作者姓名: | 陈斌 潘俊芳 林峰 叶隽 余岳林 张少敏 |
| |
作者单位: | 上海市闸北食品药品检验所,上海,200435 |
| |
摘 要: | 目的:建立石墨妒原子吸收法测定注射用磷酸肌酸钠中的微量钡.方法:以石墨炉法对注射用磷酸肌酸钠中微量钡进行测定.结果:方法回收率95.8% ~98.8%,线性范围0.0~300 μg·L-1,最低检测浓度为1μg·L-1,r=0.999 5,RSD<6.3%(n=6).结论:本方法克服了钡的记忆效应,精密度好,线性范围宽,适用于石墨炉原子吸收法测定注射用磷酸肌酸钠中的钡.
|
关 键 词: | 石墨炉原子吸收法 钡 注射用磷酸肌酸钠 |
Rearch on Determination of Trace Barium in Creatine Phosphate Sodium for Injection |
| |
Authors: | Chen Bin Pan Jun-fang Lin Feng Ye Jun Yu Yue-lin and Zhang Shao-min |
| |
Institution: | Chen Bin,Pan Jun-fang,Lin Feng,Ye Jun,Yu Yue-lin,Zhang Shao-min(Shanghai Zhabei Institute for Food and Drug Control,Shanghai 200435) |
| |
Abstract: | Objective: To establish a method for determination of trace barium in Creatine Phosphate Sodium for Injection by graphite furnace. Methods:Trace barium in Creatine Phosphate Sodium for Injection was determined by graphite furnace atomic absorption spectrometry. Restilts:The recovery was from 95.8% to 98.8%. The calibration curve was linear in the range of 0. 0 -300 μg·L^-1 for barium with r = 0. 999 5, and the relative standard deviation was less than 6. 3% ( n = 6). Conclusion: The method is linear wide- ly with good precision, and the interference of memory for barium is cecluded. It has been successfully applied to the determination of barium in creatine phosphate sodium for injection. |
| |
Keywords: | Graphite funace atomic absorption spectrometry Barium Creatine phosphate sodium for injection |
本文献已被 CNKI 维普 万方数据 等数据库收录! |
| 点击此处可从《中国药品标准》浏览原始摘要信息 |
| 点击此处可从《中国药品标准》下载免费的PDF全文 |
|