摘    要:通过对锰作业工人尿5-羟吲哚乙酸(尿5-HIAA)含量测定与空气锰、尿锰、工龄之间的比较研究,结果显示:锰作业工人尿5-HIAA与对照组之间有显著性差异(P<0.05);尿5-HIAA与空气中锰浓度呈明显负相关(r=-0.733);尿5-HIAA与尿中锰呈负相关(r=-0.301),而与工龄无相关关系

关 键 词:尿5-羟吲哚乙酸;生物监测

A Study of Urine 5-HIAA as Biological Monitoring Index for Workers Exposed to Manganese
Wu Jun,Cheng Shihua,Zhang Hong. A Study of Urine 5-HIAA as Biological Monitoring Index for Workers Exposed to Manganese[J]. Journal of Baotou Medical College, 1998, 0(3)
Authors:Wu Jun  Cheng Shihua  Zhang Hong
Abstract:To investigate the significance of urine 5-HIAA as biological monitoring index,the content of 5-HIAA in the urine of workers exposed to manganese is determined and compared with the content of air manganese and urine manganese.The relationship of 5-HIAA with the lengths of service of the workers is also investigated.The results show that there is a significant difference in urine 5-HIAA between the workers exposed to manganese and the control group (P<0 05) The content of urine 5-HIAA is negatively correlated to the level of air manganese (r=-0.733)and to the content of urine manganese(r=-0.301).However,there is no correlation between urine 5-HIAA and the length ofservice of the workers.