Short-term (90 min) diagnostic performance for acute non-ST segment elevation myocardial infarction and 30-day prognostic evaluation of a novel third-generation high sensitivity troponin I assay
Authors:Donald H. Schreiber  Chioma Agbo  Alan H.B. Wu
Affiliation:1. Department of Cardiovascular Research, King''s College London, The James Black Centre, 125 Coldharbour Lane, London SE5 9NU, United Kingdom;2. Kings College Hospital NHS Foundation Trust, Denmark Hill, London SE5 9RS, United Kingdom
Abstract:ObjectivesWe evaluated a third-generation high sensitivity “guidelines acceptable” troponin I assay (hs-cTnI) against a contemporary “clinically usable” troponin assay (cTnI).Design and methodsRemnant samples of undifferentiated emergency department (ED) patients with suspected acute coronary syndrome were enrolled. Baseline and 90-minute samples were analyzed for cTnI and hs-cTnI. Sensitivity, specificity, positive and negative predictive values for AMI and 30-day adverse cardiac events (ACE) were compared.ResultsOf 486 ED patients, there were 465 patients who had blood remaining at the presentation for the hs-cTnI assays, with 12 AMIs. At presentation, the clinical sensitivity and specificity for AMI was 75% and 97% for cTnI and 83.3 and 82.1% for hs-cTnI. There were 407 patients who had paired baseline and 90-minute blood samples for cTnI and hs-cTnI including 9 of the 12 AMI patients. The sensitivity and specificity was 77.7% and 96.5% for cTnI and 100% and 81.9% for hs-cTnI at 90 min. A Δ change of 30% increase from baseline to 90 min improved the specificity to 94.5% (95% CI 92%–96%) without lowering the sensitivity. When AMI was defined as a Δ30% change of hs-cTnI at t = 0 and 90 min and one hs-cTnI result > 99th percentile cutoff, more than 3 times as many patients met the diagnostic criteria for AMI compared to results from the normal sensitive troponin assay; 28 (6.9%) for hs-cTnI vs. 9 (2.2%) with cTnI. There were 37 in-hospital or 30-day events, producing an OR of 3.03, 95% CI: 0.86–9.59 for cTnI, and 2.54, 95% CI: 1.27–5.10 for hs-cTnI, which detected 11 more cases.ConclusionsThe hs-cTnI assay achieved a 90-minute rule out for AMI and detected more 3 times as many AMI cases. The specificity increased with the Δ30% criteria. The hs-cTnI assay also detected more cases of patient at risk for adverse cardiac events at 30 days.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号