首页 | 本学科首页   官方微博 | 高级检索  
检索        

套筒冠与卡环固位型义齿修复末端游离缺失的应力分布比较
引用本文:魏斌,陈洁,黄庆丰,金文忠,张富强.套筒冠与卡环固位型义齿修复末端游离缺失的应力分布比较[J].上海交通大学学报(医学版),2009,29(11):1288.
作者姓名:魏斌  陈洁  黄庆丰  金文忠  张富强
作者单位:上海交通大学,医学院第九人民医院口腔医学院口腔修复科,上海市口腔医学重点实验室,上海,200011
基金项目:家科技支撑计划重点项目,上海市科学技术委员会资助项目,上海市重点学科建设项目,上海市重点(特色)学科建设项目
摘    要:目的 通过模块化方式建立套筒冠及可摘局部义齿的三维有限元模型,比较三种修复体的应力分布特点。方法 调用正常牙列模型库编辑建立双侧末端游离缺失的牙列模型,在固定义齿模型库及可摘局部义齿模型库基础上,借助DELL Precision图形工作站,利用UG 5.0、HyperMesh 7.0和Abaqus 6.5软件,建立套筒冠义齿及近中支托和远中支托的可摘局部义齿三维有限元模型,进行有限元力学分析和比较。结果 在套筒冠义齿,基牙牙根及牙周膜、牙槽黏膜和牙槽骨的应力分布均匀,其牙根受力最大值(6.205 MPa)明显小于其他两种可摘局部义齿设计(分别为18.41 MPa和34.49 MPa)。结论 采用套筒冠设计修复双侧末端游离缺失病例,具有应力分布均匀,基牙受力较小的优点,有利于基牙及周围组织的健康。

关 键 词:有限元分析  套筒冠义齿  可摘局部义齿

Comparison of stress distribution on telescopic denture and clasp-retention denture for bilateral free-ended cases
WEI Bin,CHEN Jie,HUANG Qing-feng,JIN Wen-zhong,ZHANG Fu-qiang.Comparison of stress distribution on telescopic denture and clasp-retention denture for bilateral free-ended cases[J].Journal of Shanghai Jiaotong University:Medical Science,2009,29(11):1288.
Authors:WEI Bin  CHEN Jie  HUANG Qing-feng  JIN Wen-zhong  ZHANG Fu-qiang
Institution:Department of Prosthodontics, Shanghai Key Laboratory of Stomatology, College of Stomatology, The Ninth People's Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai 200011, China
Abstract:Objective To establish three dimensional finite element model libraries of telescopic dentures and removable partial dentures by means of model libraries, and compare the characteristics of stress distribution among three prostheses. Methods Normal model libraries were imported and edited, and models of bilateral free-ended cases were established. Based on the model libraries of fixed partial dentures and removable partial dentures, the finite element models of telescopic dentures and removable partial dentures with medial or distal occlusal rest were established using softwares such as DELL Precision Graphics Workstation, UG 5.0, HyperMesh 7.0 and Abaqus 6.5, then finite element stress analysis was performed. Results The stress distribution on abutment root, parodontium, alveolar mucosa and alveolar bone was uniform. The maximum value of stress on the abutment root (6.205 Mpa) was much less than those of two removable partial dentures (18.41 Mpa and 34.49 Mpa). Conclusion For bilateral free-ended cases, the telescopic denture design is uniform in stress distribution with less stress on abutment root, which is healthy to the abutment root and surrounding tissues.
Keywords:finite element analysis  telescopic denture  removable partial denture
本文献已被 万方数据 等数据库收录!
点击此处可从《上海交通大学学报(医学版)》浏览原始摘要信息
点击此处可从《上海交通大学学报(医学版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号