首页 | 本学科首页   官方微博 | 高级检索  
检索        


CT-guided cutting needle lung biopsy using modified coaxial technique: factors effecting risk of complications
Authors:Yildirim Erkan  Kirbas Ismail  Harman Ali  Ozyer Umut  Tore H Gurkan  Aytekin Cuneyt  Boyvat Fatih
Institution:Baskent University Medical School, Department of Radiology, Ankara, Turkey. drerkany@yahoo.com
Abstract:

Purpose

We present our 7-year experience with coaxial computed tomography (CT)-guided cutting needle lung biopsy and evaluate the factors affecting risk of complications.

Material and method

Between June 2000 and March 2007, we performed 225 CT-guided coaxial lung biopsies in 213 consecutive patients (161 men, 52 women). Lesion size, lesion depth, lesion location, needle-pleural angle, presence of pleural effusion, patient's position, and complications secondary to biopsy procedure (pneumothorax and bleeding) were noted. Pneumothorax was graded as mild, moderate, and severe. Bleeding complications were graded as mild, moderate, and severe.

Results

Two hundred twenty-five biopsy procedures were performed in 213 patients. The mean diameter of the lung lesion was 41.3 ± 20.1 mm. The mean distance from the peripheral margin of the lesion to the pleura was 17.3 ± 19.2 mm. After 225 procedures, there were 42 mild (18.6%), 13 moderate (5.7%), and 4 severe (1.7%) pneumothoraxes. Small hemoptysis occurred in 27 patients (12%), and mild parenchymal hemorrhage occurred in 2 patients (0.8%). The overall complication rate was 39.1%. Although, a statistically significant correlation was found between female sex, presence of emphysema, lesion depth, and pneumothorax, none of these factors had a predictive value for pneumothorax. Although, statistically significant correlations were found between female sex, lesion size, and bleeding, only lesion size had a predictive value for bleeding.

Conclusion

The most frequent and important complications of this procedure are pneumothorax and bleeding. But any factor is the predictor of pneumothorax and lesion depth is a poor predictor of bleeding complication.
Keywords:CT  Lung biopsy  Pneumothorax  Bleeding
本文献已被 ScienceDirect PubMed 等数据库收录!