Flow cytometric detection of endothelial microparticles (EMP): Effects of centrifugation and storage alter with the phenotype studied |
| |
Authors: | Sabrina H. van Ierssel Emeline M. Van Craenenbroeck Viggo F. Van Tendeloo Philippe G. Jorens |
| |
Affiliation: | a Department of Critical Care Medicine, Antwerp University Hospital (UZA), University of Antwerp, Edegem, Belgium b Laboratory of Cellular and Molecular Cardiology, Antwerp University Hospital (UZA), University of Antwerp, Edegem, Belgium c Centre for Cellular Therapy and Regenerative Medicine, Antwerp University Hospital (UZA), University of Antwerp, Edegem, Belgium |
| |
Abstract: | IntroductionEndothelial microparticles (EMP) are released into the circulation in case of endothelial disturbance, and are therefore increasingly investigated as a biomarker reflecting disease activity. Numerous pre-analytic methods have been proposed for their flow cytometric enumeration, but standardization is still lacking. In this study we evaluated the influence of centrifugation and storage conditions on EMP quantification.Materials and MethodsPlatelet-poor plasma (PPP) from 10 healthy volunteers was prepared by centrifugation at 1 550 g for 20 minutes twice. A first aliquot of PPP was analyzed immediately, a second after storage at 4 °C for 7 hours. A third and fourth aliquot were snap-frozen and stored at -80 °C for 7 and 28 days. A final aliquot was further centrifuged at 10 000 g for 10 minutes and analyzed immediately. EMP were defined as CD31+CD42b-, CD62E+, CD144+ or CD144+CD105+ particles, smaller than 1.0 µm.ResultsHigh speed centrifugation led to a significant loss of CD31+CD42b- EMP (p = 0.004). A good correlation between PPP and high speed centrifuged PPP was only found for CD144+ EMP (Kendall tau b = 0.611, p = 0.025).Storage at 4 °C did not affect EMP quantification. However, freezing at -80 °C increased CD31+CD42b- and CD62E+ EMP counts, and lowered CD144+ EMP (p < 0.05). Nevertheless, the agreement among the different storage conditions was relatively good (Kendall coefficient of concordance > 0.487; p < 0.05).ConclusionThe flow cytometric detection of EMP varies with the centrifugation protocol and the storage method used, and these changes also depend on the phenotype studied. The results of this study caution against comparing study results gathered with different EMP laboratory protocols. |
| |
Keywords: | ACD, acid citrate dextrose EMP, endothelial microparticles FITC, fluorescein isothiocyanate MP, microparticle PBS, phosphate buffered saline PE, phycoerythrin PPP, platelet poor plasma |
本文献已被 ScienceDirect 等数据库收录! |
|