首页 | 本学科首页   官方微博 | 高级检索  
     


Long-term stability of fibrinolytic factors stored at -80 °C
Authors:Jenny Hernestå  l-Boman,Jan-Hå  kan Jansson,Torbjö  rn K. Nilsson,Lars Johansson
Affiliation:a Department of Public Health and Clinical Medicine, Umeå University, Umeå, Sweden
b Department of Medicine and Geriatrics, Skellefteå County Hospital, Skellefteå, Sweden
c Department of Laboratory Medicine, Clinical Chemistry, Örebro University Hospital, and Department of Biomedicine, School of Health and Medical Sciences, Örebro University, Örebro, Sweden
d Department of Medicine, Sunderby Hospital, Luleå, Sweden
Abstract:

Introduction

Blood samples in epidemiological studies are often stored for several years and analysed at different occasions. The reagent kits are continually modified for better precision and accuracy. Our hypothesis was that epidemiological studies are affected by long-term storage and/or modifications of reagent kits.

Materials and Methods

Plasma samples stored at -80 °C from two populations were used: A case-referent study with samples collected from 1985 to 2000 and analysed 2005 (n = 1598) were used to study influence of long-term storage. A cross-sectional study analysed 1990 (n = 1558) and re-analysed 2001 (n = 78) and 2005 (n = 828) was used to study influence of reagent kit modifications. Fibrinolytic analyses included immunoassays of tPA, PAI-1 and tPA-PAI-1 complex and chromogenic substrate assays of the activities of tPA and PAI-1.

Results

Long-term storage for a median time of 11.6 years (range 5 to 20) showed an effect of time on tPA antigen R2 = 0.01, PAI-1 antigen R2 = 0.01 and tPA-PAI-1 complex R2 = 0.02. Modifications in reagent kits affected the levels of fibrinolytic factors; for tPA antigen the slope coefficients were between 0.72 and 0.95 (R2 0.47 - 0.75), whereas tPA activity showed an agreement with slope coefficients 1.06 to 1.09 (R2 0.67 - 0.93).

Conclusions

This study showed that long-term storage affects fibrinolytic variables to a negligible extent, but modifications in reagent kits introduced an element of bias. We conclude that analysis of samples on a single occasion is preferable to multiple occasions, as storage has negligible effect.
Keywords:tPA, tissue plasminogen activator   PAI-1, plasminogen activator inhibitor 1   NSHDS, Northern Sweden Health and Disease Study   VIP, Vä  sterbotten Intervention Programme   WHO-MONICA, World Health Organisation- Monitoring Trends and Determinants in Cardiovascular Disease   ISAC, Immunological specificity and accuracy control   CV, coefficient of variation   HRP, horse radish peroxidase   MAI, monoclonal anti-IgG PAI-1
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号