顶骨不同分区骨片材料力学参数差异
引用本文:汪家文,李曼,赵罡,夏冰,李竹,吴君,谢晓东,张冠军,肖朝伦.顶骨不同分区骨片材料力学参数差异[J].医用生物力学,2022,37(5):960-966.
作者姓名:汪家文  李曼  赵罡  夏冰  李竹  吴君  谢晓东  张冠军  肖朝伦
作者单位:贵州医科大学 法医学院;贵阳市公安局 云岩分局刑侦大队;湖南大学 汽车车身先进设计制造国家重点实验室;贵州医科大学 基础医学院人体解剖学教学实验中心
基金项目:国家自然科学基金项目(81660309),贵州省科技厅基金资助项目(黔科合平台人才[2018]5779-3),贵州省普通高等学校青年科技人才成长项目(黔教合KY字[2021]157)
摘    要:目的 明确顶骨不同分区骨片材料力学参数差异及其与厚度的关系。方法 将左侧顶骨分为上顶、侧顶及后顶3个分区并截取各分区骨片,利用准静态三点弯曲实验对骨片的极限载荷、极限载荷作用下的形变、弯曲强度及弹性模量进行检测,分析不同分区顶骨的材料力学参数差异,并探讨骨骼厚度与上述参数的相关性。结果 上顶、侧顶及后顶的厚度依次为上顶>后顶>侧顶(F=21.298,P<0.05)。极限载荷、弯曲强度及弹性模量在上顶(F=7.082)、侧顶(F=5.206)及后顶(F=77.748)组间差异均具有统计学意义(P<0.05)。极限载荷依次为上顶>后顶>侧顶。弯曲强度与弹性模量均为侧顶>后顶>上顶。极限载荷作用下的形变在上顶与侧顶两组间比较差异具有统计学意义(P<0.05)。极限载荷与厚度呈正相关(r=0.683,P<0.05),而弯曲强度(r=-0.467)及弹性模量(r=-0.646)均与厚度呈负相关(P<0.05)。结论 顶骨不同分区的材料力学参数及厚度均存在差异,极限载荷与厚度呈正相关,而弯曲强度与弹性模量均与厚度呈负相关。

关 键 词:顶骨  材料参数  弹性模量
收稿时间:2021/11/26 0:00:00
修稿时间:2021/12/29 0:00:00

Mechanical Parameter Differences in Different Partition of Parietal Bone
WANG Jiawen,LI Man,ZHAO Gang,XAI Bing,LI Zhu,WU Jun,XIE Xiaodong,ZHANG Guanjun,XAIO Chaolun.Mechanical Parameter Differences in Different Partition of Parietal Bone[J].Journal of Medical Biomechanics,2022,37(5):960-966.
Authors:WANG Jiawen  LI Man  ZHAO Gang  XAI Bing  LI Zhu  WU Jun  XIE Xiaodong  ZHANG Guanjun  XAIO Chaolun
Institution:School of Forensic Medicine,?Guizhou?Medical?University;Yunyan Branch Bureau Criminal Investigation Corps, Guiyang Bureau of Public Security;State Key Laboratory of Advanced Design and Manufacturing of Automobile Body, Hunan University; Experimental?Center?of?Human?Anatomy?Teaching,?Basic?Medical?College,?Guizhou?Medical?University
Abstract:Objective To determine mechanical parameter differences in different partitions of parietal bone fragments and their relationship with the thickness. MethodsThe left parietal bones were divided into three partitions, i.e., upper parietal bone (UPB), lateral parietal bone (LPB) and posterior parietal bone (PPB), and the fragments from each partition were intercepted. The ultimate load of the fragments, deformation under ultimate load, bending strength and elastic modulus under ultimate load were detected by quasi-static three-point bending test, and the differences in material mechanical parameters of parietal bones in different partitions were analyzed, as well as the correlation between bone thickness and the parameters above. Results The thickness was as follows: UPB>PPB>LPB (F=21.298, P<0.05). There were significant differences in ultimate load, bending strength and elastic modulus among the UPB (F=7.082), LPB (F=5.206) and PPB (F=7.748, P<0.05). The ultimate load was as follows: UPB>PPB>LPB. The bending strength and elastic modulus were as follows: LPB>PPB>UPB. There were significant differences in deformation between the UPB and the LPB (P<0.05). The ultimate load was positively correlated with the thickness (r=0.683, P<0.05), while the bending strength (r=-0.467) and elastic modulus (r=-0.646) were negatively correlated with the thickness (P<0.05). Conclusions The mechanical parameters and the thickness of materials in different partitions of parietal bone fragments are different. The ultimate load has a positive correlation with the thickness, while the bending strength and elastic modulus have a negative correlation with the thickness.
Keywords:parietal bone  material parameters  elastic modulus