首页 | 本学科首页   官方微博 | 高级检索  
检索        

胎儿Ⅲ°房室传导阻滞产前超声心动图分析
引用本文:张涵,;裴金凤,;杨娅,;马宁,;李嵘娟,;李宜嘉,;孙琪玮,;张晓新.胎儿Ⅲ°房室传导阻滞产前超声心动图分析[J].中华医学超声杂志,2014(7):31-34.
作者姓名:张涵  ;裴金凤  ;杨娅  ;马宁  ;李嵘娟  ;李宜嘉  ;孙琪玮  ;张晓新
作者单位:[1]首都医科大学附属北京安贞医院超声心动图一部,北京100029; [2]北京上地医院超声科,北京100029;
基金项目:北京新世纪百千万人才工程计划,北京市海淀区科技发展计划(K20110069)
摘    要:目的:总结Ⅲ°房室传导阻滞(CAVB)胎儿超声心动图特征。方法应用二维超声、M型超声及多普勒技术对10例Ⅲ°房室传导阻滞胎儿进行超声心动图检查,观察胎儿心房与心室节律及其对应关系,同时观察二尖瓣、左心室流入道及流出道、静脉导管血流频谱,并对胎儿心脏大小、心功能、房室瓣反流及心包积液等心脏结构进行观察,对Ⅲ°房室传导阻滞胎儿超声心动图特征进行总结分析。结果二维超声心动图检查提示10例Ⅲ°房室传导阻滞胎儿中2例存在心内外畸形,8例无明显心内外畸形。Ⅲ°房室传导阻滞胎儿M型超声心动图特征为房室节律分离,心房节律保持在正常范围而心室节律缓慢,多普勒超声心动图特征为二尖瓣频谱提示E峰频率缓慢,A峰频率明显快于E峰频率,E、A峰无固定对应关系。胎儿超声心动图检查提示,孕妇就诊时10例胎儿中6例心脏扩大,5例心功能不全,6例房室瓣反流,7例心包积液。超声心动图检查后10例孕妇均选择引产。结论Ⅲ°房室传导阻滞是对胎儿心功能有重要影响的缓慢型心律失常,预后不佳。M型超声结合多普勒技术可对Ⅲ°房室传导阻滞胎儿进行诊断及鉴别,对临床干预治疗及判断胎儿预后有重要意义。

关 键 词:超声心动描记术  压力  胎儿  心律失常  心性  房室传导阻滞

Diagnosis of fetal complete atrioventricular block with echocardiography
Institution:Zhang Han, Pei Jinfeng, Yang Ya, Ma Ning, Li Rongfuan, Li Yijia, Sun Qiwei, Zhang Xiaoxin. Department of Echocardiography, Beijing Anzhen Hospital, Capital Medical University, Beijing 100029, China
Abstract:Objective To evaluate the application of M-mode echocardiography and Doppler echocardiography in diagnosing complete atrioventricular block (CAVB) in fetus. Methods M-mode and Doppler echocardiography were used to screen the fetuses and bradycadia was established as CAVB in 10 cases. Atrial and ventricular rhythm was measured by M-mode echocardiography. Flow of mitral valve, left ventricular in-flow and out-flow tract, venous duct was measured by Doppler echocardiography. The characteristics and prognoses of CAVB fetus were compared and analyzed. Results CAVB was established as independence in rhythm of atrium and ventricle. The rhythm of alrium could be in normal range, while the rhythm of ventricle should be slower than normal. Enlarged chambers were observed in 6 cases, cardiac dysfunction in 5 cases, and pericardial effusion in 7 cases. Tricuspid regurgitation and mitral regurgitation existed in 5 and 1 case, respectively. All of the CAVB fetus in this study underwent abortions. Conclusions Fetal echocardiography is proven to be a useful tool to diagnose CAVB, which greatly influenced the cardiac function in fetuses. Clear diagnosis as early as possible is crucial to the treatrnent of CAVB fetus.
Keywords:Echocardiography  stress  Fetus  Arrhythmias  cardiac  Atrioventricular block
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号