两种固定融合系统在颈椎前路椎间盘切除融合手术中的应用比较
引用本文:白成瑞,李锦军,李想,费琦,李东,孟海,杨雍. 两种固定融合系统在颈椎前路椎间盘切除融合手术中的应用比较[J]. 临床和实验医学杂志, 2021, 20(1): 49-53
作者姓名:白成瑞  李锦军  李想  费琦  李东  孟海  杨雍
作者单位:首都医科大学附属北京友谊医院骨科 北京 100050;首都医科大学附属北京友谊医院骨科 北京 100050;首都医科大学附属北京友谊医院骨科 北京 100050;首都医科大学附属北京友谊医院骨科 北京 100050;首都医科大学附属北京友谊医院骨科 北京 100050;首都医科大学附属北京友谊医院骨科 北京 100050;首都医科大学附属北京友谊医院骨科 北京 100050
基金项目:首都卫生发展科研专项基金(编号:2014-2-2023)。
摘    要:目的 比较2种固定融合系统在颈椎前路椎间盘切除融合术(ACDF)中的疗效和安全性.方法 回顾性分析2017年3月至2019年3月首都医科大学附属北京友谊医院收治的58例行ACDF手术患者临床资料,根据手术方式不同分为2组,手术分别应用钛制钢板联合cage融合器(PG组)31例(35融合节段),零切迹Zero-P固定融合...

关 键 词:颈椎前路椎间盘切除融合术  Zero-P  钛制钢板  cage融合器

Comparison of two fixation fusion systems in anterior cervical discectomy and fusion surgery
Affiliation:(Department of Orthopedics,Beijing Friendship Hospital,Capital Medical University,Beijing 100050,China)
Abstract:Objective The study aimed to investigate and compare the efficiency and safety of two fixation fusion systems in anterior cervical discectomy and fusion(ACDF)surgery.Methods Retrospective analysis of Clinical data of 58 patients undergoing ACDF surgery admitted to Beijing Friendship Hospital,Capital Medical University,from March 2017 to March 2019 were retrospectively analyzed.Titanium steel plate combined with cage fusion device(plate group,PG 31 cases,35 fusion segments)and Zero-P fixation fusion device(Zero-P group,ZP 27 cases,33 fusion segments)was applicated in different operations.The operation time,blood loss,main complications,postoperative pain(VAS)score,neurological function(JOA)score,radiological data were observed and compared statistically.Results Fifty eight patients were followed up for more than 12 months.The operation time of ZP group was(99.4±20.6)min,which was shorter than that of PG group[(111.9±19.7)min],the difference was statistically significant(P<0.05).The blood loss of(35.9±14.2)mL in the ZP group was significantly less than that in the PG group[(51.0±26.6)mL],and the difference was statistically significant(P<0.05).There was no significant difference in the incidence of dysphagia symptoms in the two groups within 2 weeks after surgery(3.7%vs.12.9%)(P>0.05).The incidence of foreign body sensation in the esophagus within 2 weeks after operation in the ZP group was significantly lower than that in the PG group(7.4%vs.29.0%),and the difference was statistically significant(P<0.05).There was no statistically significant difference in the incidence of implant loosening(0 vs.3.2%)and interbody non-union within 6 months after operation(3.7%vs.6.5%)in the two groups(P>0.05).VAS score[(1.7±1.1)points vs.(1.6±1.1)points],JOA score[(15.7±0.9)points vs.(15.4±1.1)points],nerve function Recovery rate[(83.4±12.9)%vs.(79.4±15.2)%],Cobb angle of physiological curvature[(14.6±3.8)°vs.(13.7±3.4)°]and height of the posterior edge of the surgical intervertebral space[(8.0±1.5)mm vs.(7.5±1.7)mm]at 12 month follow-up in the two groups,the differences were not statistically significant(P>0.05).Conclusion During the ACDF operations,it was efficiency and safety with titanium steel plate combined with cage and Zero-P fixation fusion systems.The application of Zero-P device can make the operations more quicker,it could significantly reduce blood loss and the incidence of esophagus foreign body sensation within 2 weeks after the operation.The Zero-P device was worthy of clinical promotion.
Keywords:Anterior cervical discectomy and fusion surgery  Zero-P  Titanium steel plate  Cage