首页 | 本学科首页   官方微博 | 高级检索  
     


Optimization of non-contrast-enhanced MR angiography of the renal artery with three-dimensional balanced steady-state free-precession and time-spatial labeling inversion pulse (time-SLIP) at 3T MRI,in relation to age and blood velocity
Authors:Yasuhisa Kurata  Aki Kido  Koji Fujimoto  Kayo Kiguchi  Kyoko Takakura  Yusaku Moribata  Fuki Shitano  Yuki Himoto  Yasutaka Fushimi  Tomohisa Okada  Kaori Togashi
Affiliation:1.Department of Diagnostic Imaging and Nuclear Medicine,Kyoto University Graduate School of Medicine,Sakyoku,Japan
Abstract:

Purpose

To determine the optimal inversion time (TI) value of three-dimensional (3D) balanced steady-state free-precession time-spatial labeling inversion pulse (time-SLIP) technique for visualization of the renal artery at 3T MRI, and to assess whether the optimal TI is affected by the subject’s age and blood velocity.

Materials and methods

Forty-two healthy volunteers (range 20–67 years) were enrolled in the study and subjected to non-contrast-enhanced renal MR angiography. Five different TI values (1200, 1400, 1600, 1800, and 2000 ms) were selected for evaluation. For quantitative evaluation, the relative signal intensity (SI) of the main renal artery was compared with that of the renal medulla (Vessel-to-Kidney ratio; VKR). Blood velocity of the abdominal aorta was measured using 2D phase contrast technique. For qualitative evaluation, two radiologists scored the depiction of the renal pelvis and the quality of visualization of the renal artery.

Results

VKR is the highest at TI = 1600 ms. A strong negative correlation between age and blood velocity was demonstrated. Regarding the qualitative evaluation, the overall image scores of renal arteries were the highest at a TI = 1800 ms for both readers. The optimal TI values in subjects below 50 years of age were 1600 and 1800 ms, whereas in subjects above 50 years of age, the optimal TI value was 1800 ms.

Conclusion

The optimal TI value for the visualization of renal arteries using time-SLIP technique at 3T MRI was 1800 ms. Subjects’ age affected optimal TI and this is likely due to differences in the blood velocity of the abdominal aorta.