BI-RADS联合超声弹性成像对非哺乳期乳腺炎及乳腺癌的鉴别价值
引用本文:叶细容,刘佳.BI-RADS联合超声弹性成像对非哺乳期乳腺炎及乳腺癌的鉴别价值[J].医疗卫生装备,2021(2):56-59,77.
作者姓名:叶细容  刘佳
作者单位:鄂东医疗集团市中心医院超声影像科
摘    要:目的:探讨乳腺影像报告和数据系统(Breast Imaging Reporting and Data System,BI-RADS)联合超声弹性成像(ultrasound elastography,UE)对非哺乳期乳腺炎(non-lactating mastitis,NLM)及乳腺癌的鉴别价值.方法:回顾性选取2018...

关 键 词:超声  乳腺影像报告和数据系统  超声弹性成像  非哺乳期乳腺炎  乳腺癌

Value of BI-RADS combined with ultrasound elastography in differential diagnosis of non-lactating mastitis and breast cancer
YE Xi-rong,LIU Jia.Value of BI-RADS combined with ultrasound elastography in differential diagnosis of non-lactating mastitis and breast cancer[J].Chinese Medical Equipment Journal,2021(2):56-59,77.
Authors:YE Xi-rong  LIU Jia
Affiliation:(Department of Ultrasound Imaging,Huangshi Central Hospital of Edong Medical Group,Huangshi 435000,Hubei Province,China)
Abstract:Objective To discuss the value of Breast Imaging Reporting and Data System(BI-RADS)combined with ultrasound elastography(UE)in the differential diagnosis of non-lactating mastitis(NLM)and breast cancer.Methods Totally 159 patients with pathologically confirmed non-lactating breast masses from January 2018 to January 2019 at some hospital were selected retrospectively,including 50 cases of breast cancer and 109 ones of NLM.All the patients were given routine ultrasound(BI-RADS scoring)and UE examinations.Comparison analysis was executed over the ultrasound manifestations,BI-RADS scores and UE scores,and the values of BI-RADS,UE and the combination of them were discussed for the differential diagnosis of NLM and breast cancer.SPSS 22.0 software was used for data analysis.Results There was no statistically significant difference(P>0.05)in the percentages of marginal incompleteness between NLM and breast cancer patients.The breast cancer patient behaved obviously better in BI-RADS score,UE score,posterior echo attenuation,calcification as well as the proportions of gradeⅡandⅢinternal blood flows when compared with the NLM patient(P<0.05).The sensitivity,specialty and accuracy for differentiating NLM and breast cancer were 80.00%,82.57%and 81.76%respectively by BI-RADS,76.00%,78.90%and 77.99%respectively by UE and 96.00%,93.58%and 94.34%respectively by the combination of them.BI-RADS combined with UE gained advantages over either of them,and the differences were statistically significant(P<0.05).Conclusion BI-RADS and UE both have high differential diagnosis values for NLM and breast cancer,and BI-RADS combined with UE has higher differential diagnosis value than either of them,which was worthy for further clinical promotion.Chinese Medical Equipment Journal,2021,42(2):56-59,77]
Keywords:ultrasound  Breast Imaging Reporting and Data System  ultrasound elastography  non-lactating mastitis  breast cancer