Pseudogestational sacs: Doppler US differentiation from normal or abnormal intrauterine pregnancies
Authors:E H Dillon  A L Feyock  K J Taylor
Institution:Department of Diagnostic Radiology, Yale University School of Medicine, New Haven, CT 06510.
Abstract:Doppler ultrasound (US) evaluation of 40 empty intrauterine sac-like structures was performed to evaluate the ability of this technique to permit distinction between intrauterine pregnancy and pseudogestational sac associated with ectopic pregnancy. Proof of the location of the pregnancy was available in all cases. There were 31 intrauterine pregnancies, of which 23 were missed or incomplete abortions and eight were early normal pregnancies. With an insonating frequency of 3 MHz, the average frequency shift detected from these intrauterine pregnancies was 1.7/1.0 kHz (peak systolic/end diastolic ratio). Nine pseudogestational sacs were evaluated, of which seven demonstrated no flow and two demonstrated minimal flow that averaged 0.4/0.1 kHz. Defining intrauterine peritrophoblastic flow as a peak systolic frequency shift of 0.8 kHz or greater (equivalent to 21 cm/sec with an angle of 0 degree) correctly classifies 26 of the 31 intrauterine pregnancies and all of the nine pseudosacs. The sensitivity of the Doppler technique for the detection of intrauterine pregnancies was 84%, and the specificity was 100%.