首页 | 本学科首页   官方微博 | 高级检索  
检索        


Sutureless choledochoduodenostomy with an intraluminal degradable stent in dog model
Authors:Zhu Ling-hua  Liang Xiao  Lin Hui  Wang Yi-fan  Zhu Yi-ping  Cai Xiu-jun
Institution:Department of General Surgery, Sir Run Run Shaw Hospital, College of Medicine, the Institute of Minimally Invasive Surgery, Zhejiang University, Hangzhou, Zhejiang 310016, China
Abstract:Background It is difficult and time-consuming for carrying out conventional hand-sewn bilioenteric anastomosis, especially for small bile duct anastomosis and laparoscopic procedure. In order to simplify it, we have developed a novel procedure of sutureless bilioenteric anastomosis with an intraluminal degradable stent. This study aimed to evaluate the feasibility and safety of this technique with cholangioduodenostomy in dog model.Methods A patent intraluminal degradable stent tube for sutureless choledochoduodenostomy in dog model was made with polylactic acid in diameter of 3 mm or 4 mm. Thirty-eight dogs were randomly divided into to a stent group (SG, n=20) and a control group (CG, n=18). Dogs in the SG underwent sutureless choledochoduodenostomy with intraluminal stent, while the CG underwent conventional choledochoduodenostomy (single layer discontinuous anastomosis with absorbable suture). Dogs of each group were divided into 4 subgroups according to time of death (1,3,6, and 12 months postoperatively) to evaluate the healing of anastomosis. Operation time, intraoperative tolerance pressure of anastomosis, rate of postoperative bile leakage, bursting pressure of anastomosis were compared between the two groups. Anastomosis tissue was observed afterwards by pathology evaluation, hydroxyproline content, serum bilirubin, liver enzyme level and magnetic resonance cholangio-pancreatography (MRCP) to assess the stricture.Results All procedures were completed successfully. The surgical time of the SG was significantly less than the CG (SG: (19.2±4.3) minutes, vs. CG: (29.2±7.1) minutes, P=0.000). One bile leakage was occurred in either group. No significant difference of intraoperative tolerance pressure of anastomosis, rate of bile leakage and postoperative bursting pressure of anastomosis, anastomotic stricture, hydroxyproline content, serum bilirubin and liver enzyme level was found between the two groups. MRCP showed no anastomosis stricture and obstruction during months of follow-up.Conclusion The technique of sutureless choledochoduodenostomy with a degradable intraluminal stent is feasible and a safe procedure in this dog model.
Keywords:stent  surgical anastomosis  duodenum  common bile duct
本文献已被 维普 万方数据 PubMed 等数据库收录!
点击此处可从《中华医学杂志(英文版)》浏览原始摘要信息
点击此处可从《中华医学杂志(英文版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号