首页 | 本学科首页   官方微博 | 高级检索  
检索        


Advanced image fusion to overlay coronary sinus anatomy with real-time fluoroscopy to facilitate left ventricular lead implantation in CRT
Authors:Duckett Simon G  Ginks Matthew R  Knowles Benjamin R  Ma Yingliang  Shetty Anoop  Bostock Julian  Cooklin Michael  Gill Jas S  Carr-White Gerry S  Razavi Reza  Schaeffter Tobias  Rhode Kawal S  Rinaldi C Aldo
Institution:Division of Imaging Sciences, King's College London, BHF Centre, NIHR Biomedical Research Centre at Guy's and St Thomas' NHS Foundation Trust, London, UK. simon.duckett@kcl.ac.uk
Abstract: Background: Failure rate for left ventricular (LV) lead implantation in cardiac resynchronization therapy (CRT) is up to 12%. The use of segmentation tools, advanced image registration software, and high‐fidelity images from computerized tomography (CT) and cardiac magnetic resonance (CMR) of the coronary sinus (CS) can guide LV lead implantation. We evaluated the feasibility of advanced image registration onto live fluoroscopic images to allow successful LV lead placement. Methods: Twelve patients (11 male, 59 ± 16.8 years) undergoing CRT had three‐dimensional (3D) whole‐heart imaging (six CT, six CMR). Eight patients had at least one previously failed LV lead implant. Using segmentation software, anatomical models of the cardiac chambers, CS, and its branches were overlaid onto the live fluoroscopy using a prototype version of the Philips EP Navigator software to guide lead implantation. Results: We achieved high‐fidelity segmentations of cardiac chambers, coronary vein anatomy, and accurate registration between the 3D anatomical models and the live fluoroscopy in all 12 patients confirmed by balloon occlusion angiography. The CS was cannulated successfully in every patient and in 11, an LV lead was implanted successfully. (One patient had no acceptable lead values due to extensive myocardial scar.) Conclusion: Using overlaid 3D segmentations of the CS and cardiac chambers, it is feasible to guide CRT implantation in real time by fusing advanced imaging and fluoroscopy. This enabled successful CRT in a group of patients with previously failed implants. This technology has the potential to facilitate CRT and improve implant success. (PACE 2011; 34:226–234)
Keywords:cardiac resynchronization therapy  cardiac magnetic resonance imaging  cardiac computer tomography  coronary sinus  congestive heart failure
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号