摘    要:目的 探讨三分类血球仪中高于正常范围的白细胞数是否会对血红蛋白测量产生干扰,如果有干扰,白细胞数和血红蛋白变量之间存在什么样的对应关系.方法 用BC-1800血球仪筛选出不同白细胞数量的标本,用7180生化仪对BC-1800血球仪筛选出不同白细胞数量的标本的血红蛋白浓度进行检测,再离心去除白细胞,用7180生化仪再次测定其血红蛋白的含量.结果 超过正常范围的白细胞达到一定量时会对血红蛋白的测量产生干扰,白细胞数量越高时血红蛋白浓度的变化量越大.结论 白细胞超过正常值一定量时会使血红蛋白假性增高.

关 键 词:白细胞  血红蛋白  干扰  增高

Discussed in three classified blood cell meter the white blood cell advances to the hemoglobin survey disturbance
ZHANG Lin,LUO Qian-yuan. Discussed in three classified blood cell meter the white blood cell advances to the hemoglobin survey disturbance[J]. , 2011, 0(6): 144-145
Authors:ZHANG Lin  LUO Qian-yuan
Affiliation:(The People's Hospital of Tongiiang , Tongjiang 635700, China)
Abstract:Objective Discusses three blood cell meter classifies in the instrument to be higher than the normal range the white blood cell number whether to have the disturbance to the hemoglobin survey, if will have the disturbance, what cor- responding relationships between the white blood cell number and the hemoglobin variable will have. Method Checked the different white blood cell quantity with the BC - 1800 blood cell meter the specimen, screens the different white blood cell quantity with 7180 biochemistry meters to the BC - 1800 blood cell meter the specimen hemoglobin density to carry on the ex- amination, the centrifugal elimination white blood cell, determines its hemoglobin once more again with 7180 biochemistry meters the content. Results Surpasses the normal range the white blood cell achieves when the ration to the hemoglobin survey will have the disturbance, white blood cell quantity is higher when the hemoglobin density change quantity is bigger. Conclusion The white blood cell surpasses when the normal value ration.
Keywords:White blood cell  Hemoglobin  Disturbance  High