首页 | 本学科首页   官方微博 | 高级检索  
检索        

生物材料静态血清接触对总补体溶血活性(CH50)影响的实验研究
引用本文:胡卫建,叶长宁,李良忠,朱明华,曾怡,蒋丽.生物材料静态血清接触对总补体溶血活性(CH50)影响的实验研究[J].北京生物医学工程,2001,20(3):218-220,228.
作者姓名:胡卫建  叶长宁  李良忠  朱明华  曾怡  蒋丽
作者单位:1. 四川省人民医院,成都,610072
2. 四川省生物医学材料监测中心,成都,610041
摘    要:机体在抗原的作用下产生一系列免疫反应,血清中总补体含量的变化可反映补体活化及免疫反应程度.本文参照有关标准方法,选择八种生物材料,与血清进行体外培养,在不同时间内测定总补体溶血活性(CH50),探讨生物材料免疫反应.试验结果表明,八种材料接触血清测得CH50值均低于对照组,但每种材料降低程度有所不同,CA和PETF降低最明显,CH50定值均<40单位@ml-1,而对照组为80单位@ml-1.PP和BC材料的CH50值与对照组结果比基本一致.PETF和PES两种材料接触不同时间(30min,90min,120min)随时间的延长逐渐降低,而PETF降低较明显.该研究初步表明CA和PETF材料具有活化补体,降低CH50值,提高免疫反应的作用.

关 键 词:生物材料  血清培养  CH50变化  总补体溶血活性  实验研究
文章编号:1002-3208(2001)03-0218-03

Experemental Study of Changes of CH50 in Vitro Serum Culture Caused by Static Contact with Biomaterial
HU Weijian,YEI Changning,LI Liangzhong. People' Hospital of Sichan Province,Chengdu .ZHU Minghua,ZENG Yi,JIANG Li. Biomaterial Test Center of Sichuan Province,Chengdu.Experemental Study of Changes of CH50 in Vitro Serum Culture Caused by Static Contact with Biomaterial[J].Beijing Biomedical Engineering,2001,20(3):218-220,228.
Authors:HU Weijian  YEI Changning  LI Liangzhong People' Hospital of Sichan Province  Chengdu ZHU Minghua  ZENG Yi  JIANG Li Biomaterial Test Center of Sichuan Province  Chengdu
Institution:HU Weijian,YEI Changning,LI Liangzhong. People' Hospital of Sichan Province,Chengdu 610072.ZHU Minghua,ZENG Yi,JIANG Li. Biomaterial Test Center of Sichuan Province,Chengdu 610041
Abstract:Changes of total complement levels in surum can reflect immune response caused by antigen antibody reaction. Eight biomaterials were used to contact respectively with normal human serum for diffrent lengths of time to observe total hemolytic complement levels(CH 50 ). Immune responses of biomaterials were studied with standard methods. The result showed that the value of CH 50 measured often these materials were in vitro serum culture, was lower than that of the control group. But the decreases are different for different materials. The decreases of CH 50 of normal serum after being contracted with CH and PETF were less than those of other materials by 40 units. For two kinds of materials of PETF and PES, it decreased as length of time period increased (30,90 and 120 min). The longer the time contact with PETF of PES was the lower the CH 50 value of normal serum was. The results in the study suggest the CA and PETF materials can improve complement levels, in serum, can decrease CH 50 value, and can increase immune response.
Keywords:Biomaterial    Extracorporeal serum culture    CH    50  chang
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号