首页 | 本学科首页   官方微博 | 高级检索  
检索        


Reliability and validity of the capabilities of upper extremity test (CUE-T) in subjects with chronic spinal cord injury
Authors:Ralph J Marino  Stephen B Kern  Benjamin Leiby  Mary Schmidt-Read  M J Mulcahey
Institution:1.Department of Rehabilitation Medicine, Sidney Kimmel Medical College at Thomas Jefferson University, Philadelphia, PA, USA;2.Department of Occupational Therapy, College of Health Professions, Thomas Jefferson University, Philadelphia, PA, USA;3.Department of Pharmacology and Experimental Therapeutics, Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA, USA;4.Magee Rehabilitation Hospital, Philadelphia, PA, USA
Abstract:

Objective

To determine the reliability and validity of the capabilities of upper extremity test (CUE-T), a measure of functional limitations, in patients with chronic tetraplegia.

Design

Repeated measures.

Setting

Outpatient rehabilitation center.

Participants

Fifty subjects (36 male/14 female) with spinal cord injury (SCI) of ≥1-year duration participated. Subjects were 17–81 years old (mean 48.1 ± 18.2); neurological levels ranged from C2 through T6, American Spinal Injury Association Impairment Scale grades A–D.

Interventions

Not applicable.

Outcome measures

Intraclass correlation coefficients (ICC), weighted kappa and repeatability values for CUE-T; Spearman correlations of CUE-T with upper extremity motor scores (UEMS), and self-care and mobility portions of the Spinal Cord Independence Measure, vIII (SCIM III).

Results

Score ranges for UEMS were 8–50, CUE-T 7–135, self-care SCIM 0–20, and mobility SCIM 0–40. The ICC values for total, right, and left side scores were excellent (0.97–0.98; 95% confidence interval 0.96–0.99). Item weighted kappa values were ≥0.60 for all but five items, four of which were right and left pronation and supination. Repeatability of total score was 10.8 points, right and left sides 6.3 and 6.1 points. Spearman correlations of the total CUE-T with the UEMS and SCIM self-care and mobility scores were 0.83, 0.70, and 0.55 respectively.

Conclusions

The CUE-T displays excellent test–retest reliability, and good–excellent correlation with impairment and capacity measures in persons with chronic SCI. After revising pronation and supination test procedures, the sensitivity to change should be determined.
Keywords:Outcomes assessment  Quadriplegia  Reproducibility of results  Spinal cord injuries
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号