首页 | 本学科首页   官方微博 | 高级检索  
检索        


Location of Parapapillary Gamma Zone and Vertical Fovea Location. The Beijing Eye Study 2011
Authors:Rahul A Jonas  Camilla F Brandt  Qi Zhang  Ya X Wang  Jost B Jonas
Institution:1.Department of Ophthalmology, University Hospital of Cologne, Cologne, Germany;2.Beijing Institute of Ophthalmology, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing Tongren Hospital, Capital Medical University, Beijing, China;3.Department of Ophthalmology, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany;4.Institute of Molecular and Clinical Ophthalmology, Basel, Switzerland
Abstract:PurposeTo assess the spatial relationship between the locations of the parapapillary gamma zone and the fovea.MethodsIn a non-glaucomatous subgroup of the population-based Beijing Eye Study population, we measured the mean angle between the optic disc–fovea line and the horizontal (disc–fovea angle), the vertical distance of the fovea from the horizontal through the optic disc center (fovea vertical distance), and the location and width of the widest part of parapapillary gamma zone.ResultsThe study included 203 individuals (203 eyes; mean axial length, 24.4 ± 1.5 mm; range, 22.03–28.87 mm). The widest gamma zone part was located most often temporal horizontally (51.7%), then inferiorly (43.8%), superiorly (2.5%), and nasally (2.0%). The disc–fovea angle (mean, 7.50° ± 4.00°; range, –6.30° to –23.25°) was significantly higher (P = 0.003; i.e., fovea located more inferiorly) in eyes with the widest gamma zone inferiorly (8.46° ± 4.37°) than in eyes with the widest gamma zone temporally (6.71° ± 3.46°) and in eyes with the widest gamma zone temporally, superiorly, or nasally combined (6.75° ± 3.53°; P = 0.003). The fovea vertical distance (mean, 0.65 ± 0.33 mm; range, –0.20 to 1.67 mm) was longer (P = 0.001; i.e., fovea located more inferiorly) in eyes with the widest gamma zone inferiorly (0.73 ± 0.33 mm) than in eyes with the widest gamma zone temporally (0.58 ± 0.30 mm) and in eyes with a temporal, superior, or nasal gamma zone combined (0.58 ± 0.31 mm; P = 0.001). The fovea vertical distance increased (multivariate analysis) with the widest gamma zone location inferiorly (β = 0.25; P = 0.001) and wider width of the gamma zone (β = 0.19; P = 0.01).ConclusionsAn inferior fovea location is associated with a wider inferior gamma zone and vice versa, supporting the notion of an inferior shifting of Bruch''s membrane as the cause for an inferior gamma zone.
Keywords:parapapillary gamma zone  gamma zone  Bruch''s membrane  Bruch''s membrane opening  fovea  axial elongation  myopia
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号