血清及胆汁SIgA夹心EIA测定法 |
| |
引用本文: | 游向阳,阮克和.血清及胆汁SIgA夹心EIA测定法[J].现代免疫学,1989,9(1):37-40. |
| |
作者姓名: | 游向阳 阮克和 |
| |
作者单位: | 福建医学院附属协和医院肝胆外科研究室
(游向阳,殷凤峙,李秀全),福建医学院生化中心实验室(阮克和) |
| |
摘 要: | 本SIgA夹心酶免疫(EIA)定量分析法是以抗人分泌成分(SC)抗体包被固相载体、辣根过氧化物酶(HRP)标记抗人IgA抗体的Fab′片断作为酶标抗体。本方法灵敏度达O.625ng/孔,特异性强,批内变异系数和批间变异系数分别为5.8~9.3%和6.2~9.2%,回收率为99.6~108.7%,与相应的RIA法高度相关(r=0.961),标本用量甚微,2~4μl血清就可测定。用本方法测定117例正常成人血清,SIgA正常值为2.98~18.15μg/ml(8.04±3.60μg/mld);16份“T”管胆汁标本测定结果为40.8±25.0μg/ml。
|
关 键 词: | 血清 胆汁 免疫球蛋白A EIA |
SENSITIVE,MICROSCALE SANDWICH ENZYME IMMUNOASSAY FOR SIgA IN HUMAN SERUM AND BILE |
| |
Abstract: | This sandwich enzyme immunoassay (EIA) for specific quantitation of secretory immunoglobulin A (SIgA) in human serum and bile involved use of polystyrene plate coated with IgG of rabbit anti-human secretory component (SC) as solid phase, and (anti-IgA) Fab'-HRP conjugate. The detection limit of SIgA was 0.625ng/well without the interference by IgA and SC; coefficients of variation between-run and within-run were 6.2~9.2% and 5.8~9.3% respectively; recovery rates of SIgA in samples were 99.6~108.7%. SIgA values of 30 serum samples estimated by the EIA correlate well with those obtained by a EIA method (r = 0.961). 2~4 ul sample was enough for measurement. By using this assay, the concentrations of SIgA in 117 normal human sera and 16 T-tube drainage bile samples were determined. |
| |
Keywords: | |