首页 | 本学科首页   官方微博 | 高级检索  
     


Determination of aortic valve orifice area in aortic valve stenosis by two-dimensional transesophageal echocardiography
Authors:T Hofmann  W Kasper  T Meinertz  G Spillner  V Schlosser  H Just
Affiliation:1. Montefiore Medical Center, Department of Medicine, Division of Cardiology, Bronx, NY;2. Albert Einstein College of Medicine, Bronx, NY;1. University Clinic of Internal Medicine III, Cardiology and Angiology, Medical University of Innsbruck, Anichstrasse 35, A-6020 Innsbruck, Austria;2. University Clinic of Radiology, Medical University of Innsbruck, Anichstrasse 35, A-6020 Innsbruck, Austria;1. Division of Cardiology, Department of Medicine II, Kansai Medical University, Osaka, Japan;2. Department of Cardiovascular Surgery, Kansai Medical University, Osaka, Japan;1. Rhythmology and Electrophysiology, Department of Cardiology and Angiology, Hannover Medical School, Hannover, Germany;2. Department of Cardiac, Thoracic, Transplant and Vascular Surgery, Hannover Medical School, Hannover, Germany;1. Department of Emergency Medicine, Highland Hospital—Alameda Health System, Oakland, CA, United States;2. School of Medicine, University of California, San Francisco, CA, United States
Abstract:Two-dimensional transesophageal echocardiography was used to measure aortic valve orifice area in 24 patients with aortic valve stenosis (AS) and 15 patients without aortic valve disease. Using transesophageal echocardiography, orifice area could be measured in 20 of 24 patients with AS. With transthoracic echocardiography, orifice area could be determined in only 2 of 24 patients. In patients with AS, orifice area determined by transesophageal echocardiography was 0.75 +/- 0.34 cm2 and that calculated with Gorlin's formula was 0.75 +/- 0.32 cm2. In normal aortic valves, orifice area was 3.9 +/- 1.2 cm2 by transesophageal echocardiography. A good correlation was demonstrated between aortic valve orifice area determined using transesophageal echocardiography and calculated orifice area using Gorlin's formula in patients with AS: r = 0.92, standard error of estimate = 0.14 cm2. The absolute difference between orifice area measured with both methods ranged from 0.0 to 0.4 cm2 (mean 0.09 +/- 0.1). In 4 patients orifice area could not be determined with transesophageal echocardiography. The orifice could not be identified in 2 patients because an appropriate cross-sectional view of the aortic valve could not be achieved and in 2 patients with pinhole stenosis (aortic valve orifice area 0.3 cm2). These data show that aortic valve orifice area can be measured reliably using 2-dimensional transesophageal echocardiography.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号