首页 | 本学科首页   官方微博 | 高级检索  
检索        

超声引导下肾脏活检穿刺出血并发症分析
引用本文:章建全,刘英棣,季金娣.超声引导下肾脏活检穿刺出血并发症分析[J].中国超声医学杂志,1996(5).
作者姓名:章建全  刘英棣  季金娣
作者单位:第二军医大学,长征医院
摘    要:138例患者接受超声引导下粗针肾活检穿刺术后,血尿和肾周或肾被膜下血肿是仅见的并发症,总发生率约80.4%。血尿为主,达57.2%,13%同时合并血肿,而单纯血肿较少,约10.2%。出血发生率与活检方式有关而与穿刺频数无关,自动活检组低于手动切割组及手动负压吸引组,分别为56.2%、87.0%、88.9%。穿刺针较粗可能是潜在的相关因素。超声引导下准确定位和使用自动活检枪能减少减轻出血。

关 键 词:肾活检  超声引导  血肿  血尿

Clinical Analysis of Renal Bleeding Induced by US-guiding Biopsy
Zhang Jianquan, et al Changzhen Hospital,The second Military Medical University.Clinical Analysis of Renal Bleeding Induced by US-guiding Biopsy[J].Chinese Journal of Ultrasound in Medicine,1996(5).
Authors:Zhang Jianquan  Changzhen Hospital  The second Military Medical University
Abstract:Ultrasound-guiding renal biopsies were performed on 138 patients. Induced bleedings were seen with an overall rate 80.4%. Among the bleeding cases, hematuria accounted for 57.2% and 13% accompa nied with perirenal hematoma. A different bleeding occurence was found between automatic and manual biopsy.It was 56.2% for automatic biopsy, lower than those manual Tru-Cut and manual aspiration biopsy(87. 0%, 88.9%respectively). We suggest automatic and fine needle biopsy should be used by priority, so as to make renal biopsy more efficient and safer
Keywords:Renal biopsy US-guiding Hematoma Hematuria  
本文献已被 CNKI 等数据库收录!