构建正常胎儿超声心动图动脉导管Z评分模型
引用本文:冯涛,田力,王珂宁,顾凯莉,廖大琴,邓苗苗,王丽琦.构建正常胎儿超声心动图动脉导管Z评分模型[J].中国医学影像技术,2021,37(8):1182-1185.
作者姓名:冯涛  田力  王珂宁  顾凯莉  廖大琴  邓苗苗  王丽琦
作者单位:河南省中医院超声科, 河南 郑州 450002;河南中医药大学第三附属医院超声科, 河南 郑州 450000
基金项目:河南省高校科技创新团队支持计划(14IRTSTHN016)。
摘    要:目的 构建针对正常胎儿动脉导管(DA)内径及血流参数的Z评分模型。方法 纳入1 042胎孕20~40周单胎胎儿,以超声心动图所测胎儿DA内径及血流参数为因变量,胎儿生物学参数双顶径(BPD)、股骨长(FL)及孕周(GA)为自变量,采用回归分析获得DA内径及血流参数预测值及标准差的最佳拟合方程,并根据公式计算Z评分。结果 胎儿DA内径及血流参数均与胎儿生物学参数呈显著正相关(P均<0.05)。胎儿DA相关参数与生物学参数的最佳拟合方程均为直线回归方程。成功构建了胎儿DA内径及血流参数预测值及其标准差预测值的回归方程,并可根据方程计算胎儿DA内径及血流参数的Z评分。结论 基于胎儿生物学参数BPD、FL及GA构建的胎儿DA内径及血流参数Z评分模型可为定量评估胎儿DA内径及血流参数提供更有价值的参考。

关 键 词:胎儿  动脉导管  超声心动描记术  Z评分
收稿时间:2020/9/28 0:00:00
修稿时间:2021/5/27 0:00:00

Establishing Z-score models of normal fetal ductus arteriosus based on fetal echocardiography
FENG Tao,TIAN Li,WANG Kening,GU Kaili,LIAO Daqin,DENG Miaomiao,WANG Liqi.Establishing Z-score models of normal fetal ductus arteriosus based on fetal echocardiography[J].Chinese Journal of Medical Imaging Technology,2021,37(8):1182-1185.
Authors:FENG Tao  TIAN Li  WANG Kening  GU Kaili  LIAO Daqin  DENG Miaomiao  WANG Liqi
Institution:Department of Ultrasound, Henan Province Hospital of TCM, Zhengzhou 450002, China;Department of Ultrasound, the Third Affiliated Hospital of Henan University of TCM, Zhengzhou 450000, China
Abstract:Objective To establish Z-score models of inner diameters and blood flow parameters of fetal ductus arteriosus (DA) based on fetal echocardiography. Methods Totally 1 042 single fetuses at 20 to 40 gestational weeks were enrolled. Taken the inner diameters and blood flow parameters of fetal DA measured with echocardiography as the dependent variables, fetal biparietal diameters (BPD), femur lengths (FL) and gestational ages (GA) as the independent variables, the regression analysis was performed, and the best fitting equation for predicting values and standard deviations of DA inner diameters and blood flow parameters was obtained, then Z-scores were calculated according to the formulas. Results There were strong correlations of the inner diameter and blood flow parameters of fetal DA with biological fetal parameters (all P<0.05). The best fitting equation of fetal DA correlation parameter and biological parameter was linear regression equation. The regression equations of the predicted values of fetal DA inner diameter and blood flow parameter and its predicted value of standard deviation were successfully established, and Z-score value of the inner diameter of fetal DA and blood flow parameters could be calculated according to the equations. Conclusion Z-score models based on fetal biological parameters BPD, FL and GA might provide valuable information for quantitative evaluation on the inner diameters and blood flow parameters of fetal DA.
Keywords:fetus  ductus arteriosus  echocardiography  Z-score