首页 | 本学科首页   官方微博 | 高级检索  
     

影像引导技术辅以6自由度治疗床调整对宫颈癌患者摆位误差及靶区偏移的影响
引用本文:李永,朱丽红,杨瑞杰,王俊杰,姚丽红,周舜,赵田地. 影像引导技术辅以6自由度治疗床调整对宫颈癌患者摆位误差及靶区偏移的影响[J]. 现代肿瘤医学, 2021, 0(8): 1391-1395. DOI: 10.3969/j.issn.1672-4992.2021.08.024
作者姓名:李永  朱丽红  杨瑞杰  王俊杰  姚丽红  周舜  赵田地
作者单位:1.北京大学第三医院放射治疗科,北京 100191;2.北京妇产医院,北京 100006;3.北京大学肿瘤医院放射治疗科,北京 100142
摘    要:目的:探讨在治疗过程中患者产生的平移误差及旋转误差对靶区位置的影响,6自由度治疗床在治疗过程中的作用及靶区外放边界的变化.方法:顺序入组10例宫颈癌术后患者,所有患者常规摆位后行在线锥形束CT(CBCT)得出摆位误差后,联合6自由度治疗床进行调整,而后立即行第二次CBCT,治疗后行第三次CBCT,将所有摆位误差结果记录...

关 键 词:锥形束CT  摆位误差  6自由度治疗床  宫颈癌  靶区外放边界  图像引导放疗

The effect of image-guided technique supplemented with 6-DOF treatment bed adjustment on the positioning error and target deviation of cervical cancer
LI Yong,ZHU Lihong,YANG Ruijie,WANG Junjie,YAO Lihong,ZHOU Shun,ZHAO Tiandi. The effect of image-guided technique supplemented with 6-DOF treatment bed adjustment on the positioning error and target deviation of cervical cancer[J]. Journal of Modern Oncology, 2021, 0(8): 1391-1395. DOI: 10.3969/j.issn.1672-4992.2021.08.024
Authors:LI Yong  ZHU Lihong  YANG Ruijie  WANG Junjie  YAO Lihong  ZHOU Shun  ZHAO Tiandi
Affiliation:1.Department of Radiotherapy,Peking University Third Hospital,Beijing 100191,China;2.Beijing Obstetrics and Gynecology Hospital,Beijing 100006,China;3.Department of Radiotherapy,Tumor Hospital of Peking University,Beijing 100142,China.
Abstract:Objective:To explore the influence of translation errors and rotation errors on the target area and the surrounding normal organs in the treatment process,the role of HexaPODevo RT in the treatment process and the changes of the target area.Methods:10 patients with cervical cancer after surgery were collected.After all patients underwent routine setup and CBCT online,combining with the HexaPODevo RT was used,then the second CBCT was immediately underwent.The third CBCT after treatment was underwent.All the setup error results were recorded,to study the influence of setup error on the location and border of target area.Results:After CBCT combined with HexaPODevo RT adjusted,either system errors or random errors were reduced,and the error after treatment compared to the error after correction in four directions increased(X,Z,RX,RY).Through the HexaPODevo RT combined with CBCT online correct,the boundary of CTV to PTV can be reduced 0.64 cm in the X direction,reduced the 0.96 cm in the Y direction,reduced 1.04 cm in the Z direction.Setup errors in the target area were significantly reduced in X,Y,Z direction,RX,RY and RZ,too.Conclusion:Both the translation errors and the rotation errors on target position has great influence.HexaPODevo RT combined with online CBCT can reduce the setup errors,and can provide reliable data for the target area boundary,reduce the boundary of target.
Keywords:cone beam computed tomography(CBCT)  setup error  6 degrees of freedom bed  cervical cancer  external boundary of target area  IGRT
本文献已被 维普 等数据库收录!
点击此处可从《现代肿瘤医学》浏览原始摘要信息
点击此处可从《现代肿瘤医学》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号