Ability of code leaders to recall CPR quality errors during the resuscitation of older children and adolescents
Authors:Andrew D McInnes  Robert M Sutton  Akira Nishisaki  Dana Niles  Jessica Leffelman  Lori Boyle  Matthew R Maltese  Robert A Berg  Vinay M Nadkarni
Institution:1. The Children''s Hospital of Philadelphia, Department of Anesthesia and Critical Care Medicine, 34th Street and Civic Center Boulevard, Philadelphia, PA 19104, United States;2. The Children''s Hospital of Philadelphia, Center for Simulation, Advanced Education, and Innovation, 34th Street and Civic Center Boulevard, Philadelphia, PA 19104, United States
Abstract:

Aim

Performance of high quality CPR is associated with improved resuscitation outcomes. This study investigates code leader ability to recall CPR error during post-event interviews when CPR recording/audiovisual feedback-enabled defibrillators are deployed.

Patients and methods

Physician code leaders were interviewed within 24 h of 44 in-hospital pediatric cardiac arrests to assess their ability to recall if CPR error occurred during the event. Actual CPR quality was assessed using quantitative recording/feedback-enabled defibrillators. CPR error was defined as an overall average event chest compression (CC) rate <95/min, depth <38 mm, ventilation rate >10/min, or any interruptions in CPR >10 s. We hypothesized that code leaders would recall error when it actually occurred ≥75% of the time when assisted by audiovisual alerts from a CPR recording feedback-enabled defibrillators (analysis by χ2).

Results

810 min from 44 cardiac arrest events yielded 40 complete data sets (actual and interview); ventilation data was available in 24. Actual CPR error was present in 3/40 events for rate, 4/40 for depth, 32/40 for interruptions >10 s, and 17/24 for ventilation frequency. In post-event interviews, code leaders recalled these errors in 0/3 (0%) for rate, 0/4 (0%) for depth, and 19/32 (59%) for interruptions >10 s. Code leaders recalled these CPR quality errors less than 75% of the time for rate (p = 0.06), for depth (p < 0.01), and for CPR interruption (p = 0.04). Quantification of errors not recalled: missed rate error median = 94 CC/min (IQR 93–95), missed depth error median = 36 mm (IQR 35.5–36.5), missed CPR interruption >10 s median = 18 s (IQR 14.4–28.9). Code leaders did recall the presence of excessive ventilation in 16/17 (94%) of events (p = 0.07).

Conclusion

Despite assistance by CPR recording/feedback-enabled defibrillators, pediatric code leaders fail to recall important CPR quality errors for CC rate, depth, and interruptions during post-cardiac arrest interviews.
Keywords:CC  chest compression  AHA  American Heart Association  CPR  cardiopulmonary resuscitation  CWI  chest wall impedance  bpm  breaths per minute  ICU  Intensive Care Unit  ED  Emergency Department  ROSC  Return of Spontaneous Circulation  ETCO2  end-tidal carbon dioxide
本文献已被 ScienceDirect 等数据库收录!