A study of the minimum number of slices required for quantification of pulmonary emphysema by computed tomography] |
| |
Authors: | Y Hitsuda Y Kawasaki T Igishi K Yasuda K Kato S Matsumoto M Nakamoto K Hashimoto Y Fujii M Miyata T Sasaki E Shimizu |
| |
Affiliation: | Third Department of Internal Medicine, Faculty of Medicine, Tottori University, Japan. |
| |
Abstract: | We attempted to determine the minimum number of slices required for quantification of overall emphysema by computed tomography (CT). Forty-nine patients underwent CT scanning with a 15-mm slice interval, and 13 to 18 slices per patient were obtained. The percentage of low attenuation area (LAA%) per slice was measured with a method that we reported on previously, utilizing a CT program and NIH image. The average LAA% values for 1, 2, 3, and 6 slices evenly spaced through the lungs [LAA% (1), LAA% (2), LAA% (3), and LAA% (6)] were compared with those for all slices [LAA% (All)]. The correlation coefficients for LAA% (1), LAA% (2), LAA% (3), and LAA% (6) with LAA% (All) were 0.961, 0.981, 0.993, and 0.997, respectively. Mean differences +/- SD were -3.20 +/- 4.21%, -2.32 +/- 3.00, -0.20 +/- 1.84, and -0.16 +/- 1.26, respectively. From these results, we concluded that overall emphysema can be quantified by using at least three slices: one each of the upper, middle, and lower lung. |
| |
Keywords: | |
|
|