Incisional Negative Pressure Wound Therapy Devices Improve Short-Term Wound Complications,but Not Long-Term Infection Rate Following Hip and Knee Arthroplasty
Authors:James A. Keeney  James L. Cook  Stacee W. Clawson  Ajay Aggarwal  James P. Stannard
Affiliation:Department of Orthopaedic Surgery, University of Missouri, Columbia, MO
Abstract:

Background

The potential value of incisional negative pressure wound therapy (iNPWT) on lower extremity total joint arthroplasty (TJA) wound healing has been supported in a few retrospective studies. We performed this prospective, randomized, controlled trial to assess the impact of iNPWT on wound appearance, early complications, and late infection rates following hip and knee TJA compared with a standard surgical dressing.

Methods

Three-hundred ninety-eight patients undergoing primary or revision lower extremity TJA were randomized into iNPWT or conventional wound dressing groups. Wound healing and early complication rates were assessed at 7, 14, and 35 days after the index surgery. Late infection rates were determined at a mean 2-year follow-up.

Results

Patients treated with an iNPWT device were more likely to report wound drainage at day 7 (P = .01), but less drainage longer than 14 days (P = .04). Wound drainage was significantly higher for total hip arthroplasty patients at day 7 (P = .04), but differences were not sustained through the other time intervals. Total knee arthroplasty patients with a body mass index > 35 kg/m2 treated with an iNPWT device experienced fewer complications (1.3% vs 21.6%, P < .01) and fewer dressing-related concerns (1.3% vs 10.8%, P = .02) compared with a conventional dressing. No significant difference in late superficial or deep infection rates was identified between iNPWT and conventional dressing groups (4.0% vs 3.4%, P = .8).

Conclusion

Our study findings support improved soft tissue healing response with the use of iNPWT devices. While postoperative wound drainage may limit their value following total hip arthroplasty, incisional NPWT devices may have a targeted benefit for elective total knee arthroplasty patients with a body mass index > 35 kg/m2. Specific study in this higher-risk patient group may be helpful to define the value of iNPWT.
Keywords:incisional negative pressure wound therapy  wound healing  wound complications  total knee arthroplasty  total hip arthroplasty