多普勒超声心动描记术检测胎儿机械性QT间期
引用本文:耿丹明,王鸿,吴琳琅,王玉新.多普勒超声心动描记术检测胎儿机械性QT间期[J].中国医学影像技术,2013,29(7):1147-1150.
作者姓名:耿丹明  王鸿  吴琳琅  王玉新
作者单位:南京军区福州总医院超声诊断科, 福建 福州 350025;南京军区福州总医院超声诊断科, 福建 福州 350025;南京军区福州总医院超声诊断科, 福建 福州 350025;南京军区福州总医院超声诊断科, 福建 福州 350025
摘    要:目的 探讨多普勒超声心动描记术在测量胎儿机械性QT间期中的应用价值。 方法 对胎儿心脏无异常的早孕期、中孕期和晚孕期孕妇各100名行胎儿多普勒超声心动描记术检查。记录左心室流入道及流出道血流频谱,测量机械性QT间期,即自二尖瓣舒张期A峰结束至下一个舒张期E峰开始的时间,同时测量胎儿心率。 结果 胎儿机械性QT间期和心率呈正态分布,早孕、中孕和晚孕组胎儿机械性QT间期均值的95%可信区间分别为225.25~231.21 ms、241.21~248.79 ms和253.23~259.45 ms;不同孕期组间胎儿机械性QT间期和心率的差异均有统计学意义(P均<0.01);胎儿机械性QT间期与孕周呈正相关(r=0.499,P<0.01),胎儿心率与孕周呈负相关(r=-0.628,P<0.01)。 结论 应用多普勒超声心动描记术检测胎儿机械性QT间期简便易行,图像清晰且重复性好,可为临床诊断胎儿心律失常提供重要依据。

关 键 词:胎儿心脏  超声心动描记术  多普勒  彩色  QT间期
收稿时间:2012/11/11 0:00:00
修稿时间:2013/4/29 0:00:00

Doppler echocardiography in measurement of mechanical QT interval of the fetal heart
GENG Dan-ming,WANG Hong,WU Lin-lang and WANG Yu-xin.Doppler echocardiography in measurement of mechanical QT interval of the fetal heart[J].Chinese Journal of Medical Imaging Technology,2013,29(7):1147-1150.
Authors:GENG Dan-ming  WANG Hong  WU Lin-lang and WANG Yu-xin
Institution:Department of Ultrasound, Fuzhou General Hospital of Nanjing Military Command, Fuzhou 350025, China;Department of Ultrasound, Fuzhou General Hospital of Nanjing Military Command, Fuzhou 350025, China;Department of Ultrasound, Fuzhou General Hospital of Nanjing Military Command, Fuzhou 350025, China;Department of Ultrasound, Fuzhou General Hospital of Nanjing Military Command, Fuzhou 350025, China
Abstract:Objective To explore the value of Doppler echocardiography in measurement of mechanical QT interval of the fetal heart. Methods Totally 300 pregnant women with normal fetuses at the first, the second and the third trimester (each n=100) underwent fetal Doppler echocardiography. The blood flow spectrum of left ventricular inflow and outflow tract were recorded. The mechanical QT interval, i.e. the time interval from the end of mitral A wave to the onset of the mitral E wave was measured. In addition, the heart rate of the fetus was recorded. Results QT interval of the fetus distributed in normal fashion with 95% confidence interval of 225.25-231.21 ms in the first trimester group, 241.21-248.79 ms in the second trimester group and 253.23-259.45 ms in the third trimester group, and so was the heart rate. There were significant differences in mechanical QT interval and heart rate among different trimester groups (all P<0.01). The mechanical QT interval was positively correlated (r=0.499, P<0.01) and the heart rate was negatively correlated (r=-0.628, P<0.01) with gestational week. Conclusion Doppler echocardiography is convenient and reproducible with clear images in measurement of mechanical QT interval of the fetal heart, which may provide important diagnostic standard for fetal arrhythmia.
Keywords:Fetal heart  Echocardiography  Doppler  color  QT interval