首页 | 本学科首页   官方微博 | 高级检索  
     


Assessment of dσ*/dtmax, a Load Independent Index of Contractility, in the Canine
Authors:Adam Black  Nathan Grenz  Schaible Niccole  Peter Arndt  Jordan Lucht  Kellen Nesvig  Dan Ewert  Lawrence Mulligan
Affiliation:(1) Therapy Delivery, Medtronic, Minneapolis, MN, USA;(2) North Dakota State University, Fargo, ND, USA
Abstract:The search for a load-independent index of myocardial contractility has been a focus for nearly 100 years. Nearly all of the parameters developed have yielded insight into cardiac function but their clinical utility has been limited. A new index, dσ*/dt max, has been proposed to be useful in the clinic. This parameter is expressed as the maximum time rate of change of the pressure normalized circumferential wall stress (σ* = σ θ /P, where σ θ is circumferential wall stress and P is pressure) for a thick walled sphere model of the left ventricle (LV). This definition for a contractility index renders dσ*/dt max dependent only on LV wall volume (V m) and maximum time rate of change of the ventricular volume, dV/dt max. The index dσ*/dt max has been studied in patients with echocardiogram-derived volume, but up until this point its characteristics in canines have remained unknown. Validating this index in the canine will allow for a more intensive and wide-range investigation of the index that is not available with humans. The purpose of this study was to validate dσ*/dt max as a load-independent measure of contractility in the canine heart with the hope that it was a noninvasive assessment of contractile function. To assess the load independence of dσ*/dt max, the index was estimated over a range of preloads (end diastolic volume, EDV) during a vena caval occlusion (VCO). The study was conducted in five canines under various pacing modes [right atrial (RA), right ventricular (RV), left ventricular (LV), and biventricular (BV)] at rates of 90 or 100, and 160 bpm. The animals’ ventricular volume measurements were assessed by conductance catheter, calibrated with echocardiography. A 50 Hz filter was applied to the volume signal before differentiation to obtain dV/dt max. Echocardiography was used to calculate left ventricle mass and V m. In eight of ten cases, dσ*/dt max was significantly correlated with decreasing EDV (p < 0.05). There was also a significant correlation between dσ*/dt max and dP/dt max. With a strong correlation between the values of dσ*/dt max, dP/dt max, and EDV in all five subjects, dσ*/dt max is not load independent in the canine heart when preload is altered by a VCO. Further evaluation of this index is required to delineate the situations where dσ*/dt max can be accurately applied.
Keywords:Canine  Contractility  Load independence
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号