首页 | 本学科首页   官方微博 | 高级检索  
     


Superior Postimplant Dosimetry Achieved Using Dynamic Intraoperative Dosimetry for Permanent Prostate Brachytherapy
Authors:Tanmay Singh  Junghoon Lee  Marianna Zahurak  Hee Joon Bae  Tamey Habtu  Robert Hobbs  Yi Le  Everette C. Burdette  Daniel Y. Song
Affiliation:1. Departments of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland;2. Departments of Oncology, Biostatistics and Bioinformatics Division, Johns Hopkins University School of Medicine, Baltimore, Maryland;3. Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland;4. Merit Health Leadership Academy, Baltimore, Maryland;5. Department of Radiation Oncology, Indiana University, Bloomington, Indiana;6. Acoustic Medsystems, Savoy, Illinois
Abstract:PurposeLow-dose-rate brachytherapy is a highly effective treatment modality for prostate carcinoma, but postimplant dosimetry quality is essential and correlated with likelihood of treatment success. Registered ultrasound and fluoroscopy (iRUF) can facilitate real-time intraoperative monitoring and plan adaptation, with the aim of attaining superior dosimetric outcomes. The purpose of this research was to compare clinical postimplant dosimetric results of iRUF-guided brachytherapy against brachytherapy using standard ultrasound-guided intraoperative dosimetry methods.Methods and MaterialsWe analyzed postimplant dosimetry in 292 patients treated with Pd-103 between January 2007 and December 2018. All patients had postimplant dosimetry measured on day 0 to 1 using fused magnetic resonance/computed tomography assessment. Fifty-two patients were treated in 2 prospective clinical trials using iRUF intraoperative dosimetry, including 6 patients in a pilot study and 46 treated in a phase 2 study. Postimplant dosimetry in iRUF-treated patients was compared with dosimetry from 240 patients treated using standard (real-time ultrasound) intraoperative seed tracking.ResultsFor every parameter measuring dose coverage to the prostate, iRUF patients had significantly higher values, irrespective of adjustment for year of treatment. In adjusted analyses, parameters of dose to urethra and rectum were not significantly higher among iRUF-treated patients.ConclusionsUse of iRUF intraoperative dosimetry was associated with improved postimplant dose coverage in prostate, without associated increases in doses to urethra or rectum.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号