Comparison of high-dose-rate 192Ir source strength measurements using equipment with traceability to different standards
Affiliation:1. Swedish Radiation Safety Authority, Stockholm, Sweden;2. Radiation Physics, Department of Medical and Health Sciences and Center for Medical Image Science and Visualization, Linköping University, Faculty of Health Sciences, Linköping, Sweden;3. Norwegian Radiation Protection Authority, Österås, Norway;4. STUK-Radiation and Nuclear Safety Authority, Helsinki, Finland;5. Department of Medical Physics, Oslo University Hospital, The Norwegian Radium Hospital, Oslo, Norway;6. Department of Physics, University of Oslo, Oslo, Norway
Abstract:PurposeAccording to the American Association of Physicists in Medicine Task Group No. 43 (TG-43) formalism used for dose calculation in brachytherapy treatment planning systems, the absolute level of absorbed dose is determined through coupling with the measurable quantity air-kerma strength or the numerically equal reference air-kerma rate (RAKR). Traceability to established standards is important for accurate dosimetry in laying the ground for reliable comparisons of results and safety in adoption of new treatment protocols. The purpose of this work was to compare the source strength for a high-dose rate (HDR) 192Ir source as measured using equipment traceable to different standard laboratories in Europe and the United States.Methods and MaterialsSource strength was determined for one HDR 192Ir source using four independent systems, all with traceability to different primary or interim standards in the United States and Europe.ResultsThe measured HDR 192Ir source strengths varied by 0.8% and differed on average from the vendor value by 0.3%. Measurements with the well chambers were 0.5% ± 0.1% higher than the vendor-provided source strength. Measurements with the Farmer chamber were 0.7% lower than the average well chamber results and 0.2% lower than the vendor-provided source strength. All of these results were less than the reported source calibration uncertainties (k = 2) of each measurement system.ConclusionsIn view of the uncertainties in ion chamber calibration factors, the maximum difference in source strength found in this study is small and confirms the consistency between calibration standards in use for HDR 192Ir brachytherapy.
Keywords:Source strength determination  Calibration  Traceability
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号