脊髓造影与CTM联合应用的互补作用——附39例报告 |
| |
引用本文: | 李俊 李洪潮. 脊髓造影与CTM联合应用的互补作用——附39例报告[J]. 海南医学院学报, 1998, 4(1): 7-10 |
| |
作者姓名: | 李俊 李洪潮 |
| |
作者单位: | 海南医学院附属医院骨科 |
| |
摘 要: | 报告手术治疗的39例腰椎管狭窄症和腰椎间盘突出症以及腰椎管狭窄并椎间盘突出症,均先行脊髓造影后4h内又行脊髓CT(CTM)检查。分析其脊髓造影的总符合率为89.7%,CTM为94.9%,两者联合应用达97.4%。脊髓造影可引导CT准确扫描,CTM则可进一步明确病变部位及病理改变,并且两项检查具有明显的互补作用。
|
关 键 词: | 腰椎管狭窄症 腰椎间盘突出症 脊髓造影 脊髓造影CT扫描 |
COMBINED USE OF BOTH MYELOGRAPHY AND CTM IN DIAGNOSTING LUMBAR DISC HERNIATION AND SPINAL STENOSES AREPORT OF 39 CASES |
| |
Abstract: | 39 cases with either lumbar spinal canal stenosis or disc herniation or both treated by surgery were examined through CTM 4 hours after myelography. The results showed that the total accuracy rate of myelography was 89.7% while that of CTM was 94.9% respectively. However, the combined use of both was 97.4%, Myelography could obviously guide CT to perform accurately and CTM could further confirm the focus of the disorder and its pathological changes. The two examinations have clearly complementary effect. |
| |
Keywords: | Lumbar spinal canal stenosis Lumbar disc herniation myelography CTM |
本文献已被 CNKI 维普 等数据库收录! |