首页 | 本学科首页   官方微博 | 高级检索  
检索        

ReSTOR +3D多焦点人工晶状体植入的初步观察
引用本文:林英杰,梁先军,何锦贤,叶静,霍敏灼.ReSTOR +3D多焦点人工晶状体植入的初步观察[J].国际眼科杂志,2010,10(9):1750-1752.
作者姓名:林英杰  梁先军  何锦贤  叶静  霍敏灼
作者单位:广州中医药大学附属佛山中医院眼科,中国广东省佛山市,528000
摘    要:目的:评价ReSTOR +3D渐进衍射型多焦点人工晶状体植入术后临床效果。方法:收集我院2009-06/2009-11老年性白内障行白内障超声乳化联合AcrysofReSTOR +3D人工晶状体植入手术患者32例48眼。术后连续随访3~6(平均4±1.5)mo。观察术后末次随访时裸眼远、中、近视力及最佳矫正远、中,近视力、脱镜率、人工晶状体的位置。结果:术后裸眼远视力为0.85±0.17,术后裸眼中距离视力为0.65±0.15,术后裸眼近视力为0.64±0.13,术后最佳矫正远视力为0.96±0.14,术后最佳矫正中距离视力为0.69±0.17,术后最佳矫正近视力为0.77±0.15。脱镜率为84%。裂隙灯检查见人工晶状体居中,无倾斜。随访期间未发现后发性白内障。结论:ReSTOR+3D衍射型多焦点人工晶状体能为患者提供满意的全程视力。

关 键 词:渐进衍射型多焦点  人工晶状体  ReSTOR  +3DIOL

Preliminary result of ReSTOR +3D apodized diffractive multifocal IOL implantation
Ying-Jie Lin,Xian-Jun Liang,Jin-Xian He,Jing Ye and Min-Zhuo Huo.Preliminary result of ReSTOR +3D apodized diffractive multifocal IOL implantation[J].International Journal of Ophthalmology,2010,10(9):1750-1752.
Authors:Ying-Jie Lin  Xian-Jun Liang  Jin-Xian He  Jing Ye and Min-Zhuo Huo
Institution:Department of Ophthalmology,Foshan Hospital of TCM,Foshan 528000,Guangdong Province,China;Department of Ophthalmology,Foshan Hospital of TCM,Foshan 528000,Guangdong Province,China;Department of Ophthalmology,Foshan Hospital of TCM,Foshan 528000,Guangdong Province,China;Department of Ophthalmology,Foshan Hospital of TCM,Foshan 528000,Guangdong Province,China;Department of Ophthalmology,Foshan Hospital of TCM,Foshan 528000,Guangdong Province,China
Abstract:AIM:To evaluate the visual performance of the Acrysof ReSTOR +3D intraocular lens (IOL) (SN6AD1,Alcon) implantation. ·METHODS:Totally 32 patients 48 eyes were implanted with the Alcon ReSTOR +3D apodized diffractive multifocal IOL. The mean follow-up was 4±1.5 months(range form 3 to 6 months). Distant uncorrected ,best-corrected visual acuity; near uncorrected,best-corrected visual acuity; intermediate visual acuity,best-corrected visual acuity,spectacle independency and the position of the IOLs were observed. ·RESULTS:Distance uncorrected visual acuity was 0.85±0.17 and distant best-corrected visual acuity was 0.96±0.14. Near uncorrected visual acuity was 0.64±0.13 and near best-corrected visual acuity was 0.77±0.15. Inter-mediate uncorrected visual acuity was 0.65±0.15 and intermediate best-corrected visual acuity was 0.69±0.17. Spectacle independency was 84%. No tilt or decentration of the IOL were observed. Posterior capsular opacification was not found in the follow-up. ·CONCLUSION:The Acrysof ReSTOR +3D IOL provides a satisfactory full range of vision.
Keywords:ReSTOR+3D IOL
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《国际眼科杂志》浏览原始摘要信息
点击此处可从《国际眼科杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号