首页 | 本学科首页   官方微博 | 高级检索  
     

真空垫在CT引导下肺部穿刺活检中的应用
引用本文:姚国荣,陆中杰,周进淇. 真空垫在CT引导下肺部穿刺活检中的应用[J]. 中国介入影像与治疗学, 2012, 9(8): 579-581
作者姓名:姚国荣  陆中杰  周进淇
作者单位:浙江大学医学院附属第一医院放疗中心,浙江杭州,310009
摘    要:目的探讨真空垫固定在CT引导下肺部穿刺活检中的应用价值。方法从1256例接受CT引导下肺部穿刺活检的患者中随机选取120例,分为2组:A组60例接受激光定位配合真空垫固定下的肺部穿刺活检,B组60例接受常规CT引导下穿刺活检,比较两组的首次穿刺成功率。结果A组穿刺成功率100%(60/60),其中首次穿刺成功率为86.67%(52/60),并发症发生率11.67%(7/60);B组58例患者纳入研究,穿刺成功率为96.55%(56/58),其中首次穿刺成功率为70.69%(41/58),并发症发生率17.24%(10/58)。A组首次穿刺成功率高于B组(X^2=4.508,P〈0.05)。结论使用真空垫固定行CT引导下肺部穿刺活检操作简便,安全可靠,值得推广。

关 键 词:  活组织检查  体层摄影术  x线计算机  激光引导
收稿时间:2012-03-07
修稿时间:2012-04-05

Vacuum bag fixation in CT guided percutaneous lung biopsy
YAO Guo-rong,LU Zhong-jie and ZHOU Jin-qi. Vacuum bag fixation in CT guided percutaneous lung biopsy[J]. Chinese Journal of Interventional Imaging and Therapy, 2012, 9(8): 579-581
Authors:YAO Guo-rong  LU Zhong-jie  ZHOU Jin-qi
Affiliation:Department of Radiotherapy, the First Affiliated Hospital of Medical College, Zhejiang University, Hangzhou 310009, China;Department of Radiotherapy, the First Affiliated Hospital of Medical College, Zhejiang University, Hangzhou 310009, China;Department of Radiotherapy, the First Affiliated Hospital of Medical College, Zhejiang University, Hangzhou 310009, China
Abstract:Objective To explore the clinical value of vacuum bag fixation for CT-guided lung biopsy.Methods Totally 120 patients were selected from 1256 patients who underwent lung biopsy under CT guidance,and the patients were divided into two groups: Group A including 60 patients who received vacuum bag fixation,group B including 60 patients who received biopsy with routine fixation.Successful rate of the first puncture was compared between two groups.Results Successful rate of puncture in group A was 100%(60/60),and the successful rate of the first puncture was 86.67%(52/60),and the occurrence rate of complication was 11.67%(7/60).Fifty-eight patients were enrolled in group B,the successful rate of puncture was 96.55%(56/58),the successful rate of the first puncture was 70.69%(41/58),and the occurrence rate of complications was 17.24%(10/58).Statistical difference of the successful rate of the first puncture in group A was higher than that in group B(χ2=4.508,P<0.05).Conclusion Under CT guidance,vacuum bag fixation for lung biopsy is convenient,safe,reliable,and worthy generalizing.
Keywords:Lung  Biopsy  Tomography, X-ray computed  Laser-guided
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《中国介入影像与治疗学》浏览原始摘要信息
点击此处可从《中国介入影像与治疗学》下载全文