首页 | 本学科首页   官方微博 | 高级检索  
检索        

主动脉夹层假腔开口于肾动脉的腔内隔绝术
引用本文:景在平,赵珺,冯翔,赵志青,包俊敏,陆清声.主动脉夹层假腔开口于肾动脉的腔内隔绝术[J].中国医学影像技术,2002,18(9):859-861.
作者姓名:景在平  赵珺  冯翔  赵志青  包俊敏  陆清声
作者单位:全军血管外科研究所,上海长海医院血管外科,上海,200433
基金项目:全军杰出人才基金资助项目,项目编号(98J005);上海卫生系统百人计划基金资助项目,项目编号(97BR047);第二军医大学长海医院学科攀登计划资助项目.
摘    要:目的 探讨胸主动脉夹层假腔开口于肾动脉的腔内隔绝方式。方法 MR评估发现胸主动脉夹层动脉瘤近端裂口位于降主动脉 ,远端裂口位于左肾动脉。采用TALENT移植物封闭近端裂口 ,自制“礼帽状”支架 人造血管复合体移植物用于封闭肾动脉裂口。结果 操作获得成功 ,两种移植物均成功植入 ,近端裂口完全封闭 ,远端裂口残余少量内漏 ,肾动脉保持通畅。结论 肾动脉内置入人造血管 金属支架复合体移植物是可行的 ,是对这种微创技术适应证的进一步扩展。

关 键 词:主动脉夹层  肾动脉  支架-人造血管  血管腔内
文章编号:1003-3289(2002)09-0859-03
收稿时间:2002/4/19 0:00:00
修稿时间:2002年4月19日

Endovascular Exclusion for Aortic Dissection with Distal Tear at Renal Artery
JING Zai-ping,ZHAO Jun,FENG Xiang,ZHAO Zhi-qing,BAO Jun-min and LU Qing-sheng.Endovascular Exclusion for Aortic Dissection with Distal Tear at Renal Artery[J].Chinese Journal of Medical Imaging Technology,2002,18(9):859-861.
Authors:JING Zai-ping  ZHAO Jun  FENG Xiang  ZHAO Zhi-qing  BAO Jun-min and LU Qing-sheng
Institution:Institute of Vascular Surgery of PLA, Department of Vascular Surgery, Changhai Hospital, the Second Military Medical University, Shanghai200433,China;Institute of Vascular Surgery of PLA, Department of Vascular Surgery, Changhai Hospital, the Second Military Medical University, Shanghai200433,China;Institute of Vascular Surgery of PLA, Department of Vascular Surgery, Changhai Hospital, the Second Military Medical University, Shanghai200433,China;Institute of Vascular Surgery of PLA, Department of Vascular Surgery, Changhai Hospital, the Second Military Medical University, Shanghai200433,China;Institute of Vascular Surgery of PLA, Department of Vascular Surgery, Changhai Hospital, the Second Military Medical University, Shanghai200433,China;Institute of Vascular Surgery of PLA, Department of Vascular Surgery, Changhai Hospital, the Second Military Medical University, Shanghai200433,China
Abstract:Objective To disscuss the endovascular therapy for the aortic dissection with the distal tear at renal artery. Methods Two tears, the proximal one at the decending aorta and the distal one at the left renal artery, were revealed by MRA. Talent stent grafts were used to seal the proximal tear, while the stent graft like customed hat was used to seal the distal ones. Results Two kinds of stent grafts were deployed successfully, and the two tears were both sealed. The renal artery remained patent. Conclusion For the dissection with the tear at the renal artery, this method was fiseable and the indications of endovascular exclusion was further expanded.
Keywords:Aortic dissection/thoracic  Renal artery  Stent  graft  Endovascular
本文献已被 CNKI 维普 万方数据 等数据库收录!