Abstract: | For clearing up the inhalative load by welding fumes and gases of arc welders in industrial workshops mainly working on Cr-Ni-steels the following welding processes were studied: tungsten inert-gas (TIG), electrode-by-hand (EH), metal inert-gas (MIG), and plasma cutting (plasma). From the total load by welding fumes follows the rank TIG less than EH less than plasma less than MIG. Observing the maximum allowable concentration (MACD) for the total welding fume, no MACD for Cr and Ni was found exceeded. Regarding the welding gases ozone and CO no limit values were exceeded. From the results conclusions were made. |