LISS钢板加同种异体骨移植治疗股骨远端骨折
引用本文:卫永鲲,马慧玲,刘丰虎,杨 磊,于 洋,尹 伟. LISS钢板加同种异体骨移植治疗股骨远端骨折[J]. 中国组织工程研究, 2011, 15(30): 5565-5568. DOI: 10.3969/j.issn.1673-8225.2011.30.014
作者姓名:卫永鲲  马慧玲  刘丰虎  杨 磊  于 洋  尹 伟
作者单位:1陕西省汉中市3201医院骨科,陕西省汉中市 7230002陕西省汉中职业技术学院,陕西省汉中市 723000
摘    要:背景:LISS钢板可在微创下固定骨折,减少血供的破坏,LISS钢板与同种异体骨同时应用可提高骨折的愈合率。目的:观察LISS钢板加同种异体骨移植治疗股骨远端骨折的疗效。方法:2009/2010采用LISS钢板加同种异体骨移植治疗股骨远端粉碎骨折73例进行修复重建。男47例,女26例,年龄32~76岁。交通事故61例,高处坠落9例,其他3例。闭合性损伤57例,开放性损伤16例。根据AO分型,A型19例,B型13例,C型41例。结果与结论:根据Kolment膝关节功能评定标准判定,优27例,良39例,差4例(1例为尿毒症患者),优良率为90.4%。结果显示LISS钢板加同种异体骨移植治疗股骨髁骨折效果满意。

关 键 词:股骨远端粉碎骨折  同种异体  骨移植  LISS钢板  植入物  
收稿时间:2011-03-15

Less Invasive Stabilisation System plating and bone allograft for distal femoral fractures
Wei Yong-kun,Ma Hui-ling,Liu Feng-hu,Yang Lei,Yu Yang,Yin Wei. Less Invasive Stabilisation System plating and bone allograft for distal femoral fractures[J]. Chinese Journal of Tissue Engineering Research, 2011, 15(30): 5565-5568. DOI: 10.3969/j.issn.1673-8225.2011.30.014
Authors:Wei Yong-kun  Ma Hui-ling  Liu Feng-hu  Yang Lei  Yu Yang  Yin Wei
Affiliation:1Department of Orthopedics, the 3201 Hospital of Hanzhong City, Hanzhong  723000, Shaanxi Province, China
2Hanzhong Vocational and Technical College, Hanzhong  723000, Shaanxi Province, China
Abstract:BACKGROUND:Less Invasive Stabilisation System (LISS) plate can fix fractures microinvasively, reduce damage to the blood supply. LISS plate combined with bone allograft can improve the healing rate of fractures.OBJECTIVE:To observe the effects of LISS locking plate fixation and bone allograft on distal femur fractures. METHODS:Seventy-three patients received LISS locking plate fixation and bone allograft for treatment of comminuted fracture of the distal femur from 2009 to 2010, including 47 males and 26 females, aged 32-76 years. Sixty-one cases suffered from traffic accident, 9 suffered from falls, and 3 suffered from other reasons. There were 57 cases of blunt injury and 16 of open injury. According to AO typing, there were 19 of type A, 13 of type B, and 41 of type C. RESULTS AND CONCLUSION: Based on the Kolment evaluation standards, the effects were excellent in 27 cases, good in 39 cases, and poor in 4 cases. The excellent and good rate was 90.4%. The LISS locking plate fixation plus bone allograft is good for treatment of distal femur fractures.
Keywords:
点击此处可从《中国组织工程研究》浏览原始摘要信息