首页 | 本学科首页   官方微博 | 高级检索  
     

三重固定纽扣钢板肩锁关节复位的生物力学
引用本文:吕书军,曹 勇,周广鍳,王以进. 三重固定纽扣钢板肩锁关节复位的生物力学[J]. 中国组织工程研究, 2011, 15(9): 1675-1679. DOI: 10.3969/j.issn.1673-8225.2011.09.038
作者姓名:吕书军  曹 勇  周广鍳  王以进
作者单位:南通市海安县人民医院骨科,江苏省海安县226600
摘    要:背景:研究表明喙锁韧带在维持肩锁关节的稳定性中起重要作用,因而重建喙锁韧带至关重要。目的:对比观察三重固定纽扣钢板重建肩锁关节复位的生物力学性能。  方法:采集新鲜肩关节标本15具,造成肩锁关节脱位,分别行三重固定纽扣钢板重建和双Endobutton钢板重建,进行生物力学应力分析,对照比较两者重建肩锁关节的性能和效果。  结果与结论:三重固定纽扣钢板技术在应力-应变关系中,强度比正常喙锁韧带和双Endobutton钢板分别高25%和15%,弹性模量分别高17%和14%,轴向刚度分别高24%和14%,差异均有显著性意义(P < 0.05)。 结果提示,三重固定纽扣钢板重建肩锁关节的生物力学性能,在强度、刚度均远超过初始的喙锁韧带的生物力学性能,而三重固定纽扣钢板重建肩锁关节复位的性能和效果比双Endobutton钢板重建更具有力学上的优势。

关 键 词:肩锁关节  喙锁韧带  固定纽扣钢板  双Endobutton钢板  生物力学  
收稿时间:2010-09-06

Biomechanics of acromioclavicular joint reduction using triple button plates
Lü Shu-jun,Cao Yong,Zhou Guang-jian,Wang Yi-jin. Biomechanics of acromioclavicular joint reduction using triple button plates[J]. Chinese Journal of Tissue Engineering Research, 2011, 15(9): 1675-1679. DOI: 10.3969/j.issn.1673-8225.2011.09.038
Authors:Lü Shu-jun  Cao Yong  Zhou Guang-jian  Wang Yi-jin
Affiliation:Department of Orthopaedics, Haian People's Hospital, Haian   226600, Jiangsu Province, China
Abstract:BACKGROUND:Coracoclavicular ligament plays an important role in maintaining acromioclavicular joint (ACJ) stability, thus, ACJ reconstruction is necessary.  OBJECTIVE:To observe the biomechanics of acromioclavicular joint reduction using triple button plates.  METHODS:Fifteen fresh shoulders were collected, prepared for ACJ dislocation, and reconstructed using triple button plate or double Endobutton. Biomechanical stress analysis was used to compare performances and the effects of two methods. RESULTS AND CONCLUSION:The stress-strain relationship showed that, strength of triple button plate was 25% and 15% larger than the normal coracoclavicular ligament and double Endobutton plate, the elastic modulus was 17% and 14%, and the axial stiffness was 24% and 14%, respectively. There were significant differences between the two groups (P < 0.05). Triple button plates are superior to initial ACJ in strength and stiffness. Obviously, triple fixed-button reconstruction has mechanical advantage than reconstruction plate has much mechanical advantage than the double Endobutton plate.
Keywords:
点击此处可从《中国组织工程研究》浏览原始摘要信息
点击此处可从《中国组织工程研究》下载全文