首页 | 本学科首页   官方微博 | 高级检索  
     


Increased bone turnover as reflected by biochemical markers in patients with potentially unstable fixation of the tibial component
Authors:Ming?G.?Li  author-information"  >  author-information__contact u-icon-before"  >  mailto:mingguo@cyllene.uwa.edu.au"   title="  mingguo@cyllene.uwa.edu.au"   itemprop="  email"   data-track="  click"   data-track-action="  Email author"   data-track-label="  "  >Email author,Kim?Thorsen,Kjell?G.?Nilsson
Affiliation:(1) Department of Orthopaedics, Umeå University, 90185 Umeå, Sweden;(2) Department of Surgery (Orthopaedics), University of Western Australia, WA 6009 Nedlands, Australia;(3) Perth Orthopaedic Institute, Gate 3, Verdun Street, WA 6009 Nedlands, Australia
Abstract:Introduction Whether biochemical markers of bone metabolism can be used in assessing the conditions of implant fixation is unknown. In this study, the serum levels of three bone markers were measured prospectively in patients undergoing total knee arthroplasty (TKA) to determine if patients with different fixation conditions of the tibial component showed any differences in the levels of the markers.Materials and methods The fixation of the tibial component in 40 knees (40 patients, 14 male and 26 female, average age 71 years) was assessed by radiostereometric analysis (RSA), and based upon the pattern of migration, implants with stable fixation (n=25) and potentially unstable fixation (n=15) were identified. Serum levels of carboxyterminal propeptide of type I procollagen (PICP), osteocalcin (OC) and cross-linked carboxyterminal telopeptide of type I collagen (ICTP) were assessed and compared between the two fixation groups. Blood samples were obtained preoperatively (baseline) and repeated postoperatively at 1 week, 3, 6, 12, and 24 months.Results The baseline levels of the markers were statistically the same (p>0.05) between the two fixation groups. Postoperatively, ICTP levels in the unstable group were significantly higher than in the stable group from 6 to 24 months (p=0.02). Levels of OC in the unstable group were higher at 12 and 24 months compared with the stable group, reaching statistical significance only at 12 months (p=0.03). No difference in the levels of PICP was found between the two groups.Conclusion The findings indicate a more active bone turnover probably at the bone-cement/implant interface in knees with potentially unstable fixation. It reveals the potential value for biochemical markers in monitoring implant fixation and aseptic loosening and suggests a possibility for improving implant fixation by drugs which inhibit osteolysis.
Keywords:Biochemical markers  Total knee arthroplasty  Implant fixation  Bone-implant interface  Radiostereometric analysis
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号