摘    要:目的评价CT引导下经皮穿刺活检肺内小结节(≤2.0 cm)的价值。方法采用18~20G自动活检针对60例64个肺小结节(5个直径0.7~1.0 cm,59个直径1.1~2.0 cm)进行经皮穿刺活检。结果对92.19%(59/64)结节取得足够量组织,经病理检查获得定性诊断,其中恶性结节占66.10%(39/59),良性病灶33.90%(20/59)。气胸发生率为32.81%(21/64),2例次(2/64,3.13%)须行闭式胸腔引流。结论 CT引导下经皮肺穿刺活检术对≤2.0 cm肺结节的诊断准确率高,并发症少,是一种安全有效、准确率高的诊断方法。

关 键 词:肺结节  活组织检查  体层摄影术,X线计算机
收稿时间:2011-04-11
修稿时间:2011-05-18

CT-guided percutaneous biopsy of small lung nodules
ZHANG Yan-qun,TIAN Shu-ping,WANG Zhan-yu,SHI Li-jing,LI Xiao-juan,WANG Shou-hai,MENG Yu-hong and GUO Kun. CT-guided percutaneous biopsy of small lung nodules[J]. Chinese Journal of Interventional Imaging and Therapy, 2011, 8(4): 263-266
Authors:ZHANG Yan-qun  TIAN Shu-ping  WANG Zhan-yu  SHI Li-jing  LI Xiao-juan  WANG Shou-hai  MENG Yu-hong  GUO Kun
Affiliation:CT Room, Department of Imaging,PLA Navy General Hospital, Beijing 100048, China;CT Room, Department of Imaging,PLA Navy General Hospital, Beijing 100048, China;CT Room, Department of Imaging,PLA Navy General Hospital, Beijing 100048, China;CT Room, Department of Imaging,PLA Navy General Hospital, Beijing 100048, China;CT Room, Department of Imaging,PLA Navy General Hospital, Beijing 100048, China;CT Room, Department of Imaging,PLA Navy General Hospital, Beijing 100048, China;Department of Pathology,PLA Navy General Hospital, Beijing 100048, China;Department of Pathology,PLA Navy General Hospital, Beijing 100048, China
Abstract:Objective To evaluate the diagnostic accuracy and complication rate of CT-guided percutaneous biopsy of small lung nodules(diameter ≤ 2.0 cm).Methods A total of 60 patients with 64 small lung nodules underwent CT-guided percutaneous biopsy.Biopsy needles of 18—20G were used.Among 64 nodules,the diameters were 0.7—1.0 cm in 5,while were 1.1—2.0 cm in 59.Results The overall diagnostic accuracy was 92.19%(59/64).Pneumothorax occurred in 21 punctures(32.81%,21/64),and thoracostomy insertion was performed after 2 punctures(3.13%,2/64).There were 39 nodules(39/59,66.10%) confirmed malignant and 20(20/59,33.90%) confirmed benign.Conclusion CT-guided percutaneous lung biopsy is a safe and effective diagnostic method to ≤2.0 cm pulmonary nodules.
Keywords:Pulmonary nodule  Biopsy  Tomography, X-ray computed